Hardness — gpg, How to set the time of day – Aqua-Pure NWS200 User Manual

Page 14

Advertising
background image

3-2

Model(s) 200

HARDNESS — gpg

Persons In

Family

5

10

15

20

25

30

35

40

45

50

55

60

1

1

1

1

1

1

1

1

1

1

1

1

2

2

1

1

1

1

1

2

2

2

2

2

2

3

3

1

1

1

2

2

2

2

3

3

3

3

4

4

1

1

2

2

2

3

3

3

4

4

4

6

5

1

1

2

2

3

3

4

4

4

6

6

6

6

1

2

2

3

3

4

4

6

6

6

6

12

7

1

2

2

3

4

4

6

6

6

12

12

12

8

1

2

3

3

4

6

6

6

12

12

12

12

9

1

2

3

4

4

6

6

12

12

12

12

12

10

1

2

3

4

6

6

12

12

12

12

12

12

HOW TO SET TIME CLOCK REGENERATION CONTROL:

HOW TO SET DAYS ON WHICH WATER SOFTENER IS TO REGENERATE:

Rotate the skipper wheel until the number “1” is at the red pointer. Set the days that regeneration is to occur by sliding tabs on the skipper wheel outward to
expose trip fi ngers. Each tab is one day. Finger at red pointer is tonight. Moving clockwise from the red pointer, extend or retract fi ngers to obtain the desired
regeneration schedule.

HOW TO SET THE TIME OF DAY:

1)

Press and hold the red button in to disengage the drive gear.

2)

Turn the large gear until the actual time of day is opposite the time of day pointer.

3) Release the red button to again engage the drive gear.

4)

Time of regeneration is preset for 2:00 a.m.

HOW TO MANUALLY REGENERATE YOUR WATER SOFTENER AT ANY TIME.

Turn the manual regeneration knob clockwise.

A slight, clockwise movement of the manual regeneration knob engages the program wheel and starts the regeneration program.

The black center knob will make one revolution in the following approximately three hours and stop in the position shown in the drawing (Service Position).

Conditioned water may be drawn after rinse water stops fl owing from the water softener drain line.

Advertising