SAFETY INFORMATION

EXPLANATION OF SIGNAL WORD CONSEQUENCES

WARNING

CAUTION

IMPORTANT NOTES

Read, understand, and follow all safety information contained in these instructions prior to installation and use of the

Aqua-Pure

®

AP800 Series Whole House Water Filters. Retain these instructions for future reference.

Intended use:

The Aqua-Pure

®

AP800 Series Whole House Water Filters are intended for use in filtering potable water in homes and have not

been evaluated for other uses. These filters are typically installed at the point of entry, and should be installed by qualified

professional installers according to these installation instructions.

CAUTION

WARNING

Indicates a potentially hazardous situation, which, if not avoided, could result in death or

serious injury and/or property damage.
Indicates a potentially hazardous situation, which, if not avoided, may result in minor or

moderate injury and/or property damage.
Indicates a potentially hazardous situation, which, if not avoided, may result in property damage.

To reduce the risk associated with choking:

Do not allow children under 3 years of age to have access to small parts during the installation of this product.
To reduce the risk associated with ingestion of contaminants:

Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after

the system.

To reduce the risk associated with hazardous voltage due to an installer drilling through existing electric wiring or

water pipes in the area of installation:

Do not install near electric wiring or piping which may be in the path of a drilling tool when selecting the position to

mount the filter bracket.

To reduce the risk of physical injury:

• Shut off inlet water supply and depressurize system as shown in manual prior to cartridge removal.
To reduce the risk associated with a hazardous voltage:

• If the home electrical system requires use of the cold water system as an electrical safety ground, a jumper must be used

to ensure a sufficient ground connection across the filter installation piping — refer installation to qualified personnel.

To reduce the risk associated with back strain:

• Follow safe lifting procedures.

To reduce the risk associated with property damage due to water leakage:

Read and follow Use Instructions before installation and use of this system.

• Installation and use MUST comply with all state and local plumbing codes.

Protect from freezing. Drain filter when temperatures are expected to drop below 40°F (4.4°C).

Do not install systems in areas where ambient temperatures may go above 110° F (43.3° C).

Do not install if water pressure exceeds 100 psi (690 kPa). If your water pressure exceeds 80 psi (552 kPa), you must

install a pressure limiting valve. Contact a plumbing professional if you are uncertain how to check your water pressure.

Do not install where water hammer conditions may occur. If water hammer conditions exist you must install a

water hammer arrester. Contact a plumbing professional if you are uncertain how to check for this condition.

• Where a backflow prevention device is installed on a water system, a device for controlling pressure due to thermal

expansion must be installed.

Do not install on hot water supply lines. The maximum operating water temperature of this system is 100°F (37.8°C).

Do not use a torch or other high temperature sources near system, cartridges, plastic fittings or plastic plumbing.

• On plastic fittings, never use pipe sealant or pipe dope. Use PTFE thread tape only, pipe dope properties may

deteriorate plastic.

• Take care when using pliers or pipe wrenches to tighten plastic fittings, as damage may occur if over tightening occurs.

Do not install in direct sunlight or outdoors.

Do not install near water pipes which will be in path of a drilling tool when selecting the position to mount the bracket.

• Mount system in such a position as to prevent it from being struck by other items used in the area of installation.

• Ensure that the location and fasteners will support the weight of the system when installed and full of water.

Ensure all tubing and fittings are secure and free of leaks.

• SHUT OFF FUEL OR ELECTRIC POWER SUPPLY TO WATER HEATER after water is shut off.

• The disposable cartridge must be replaced every 6 months, at the rated capacity or sooner if a noticeable reduction

in flow rate occurs.

• Failure to follow instructions will void warranty.

• Allow a minimum of 2” (5.1 cm) clear space under filter to facilitate cartridge change.

• Install with the inlet and outlet ports as labeled. Make sure not to reverse connections.

• Some local codes may require the use of a licensed plumber or certified installer when disrupting a potable water line.

• Before starting installation, shut off main water supply and drain pipes.