Description

Function and application

The TOUCH DIM LS/PD LI sensor regulates the brightness

at the workplace and in office areas to increase the working

comfort and to save energy.
The sensor can be installed in luminaires (e.g. floor standing

luminaires) or in false ceilings.

Function

The sensor measures the brightness in the area to be regulated

and keeps this to an adjustable set value by introducing artificial

light according to the amount of daylight available.
The sensor also detects the movements of people.
As daylight increases the artificial light is reduced . The sensor

no longer detects any motions, it switches the luminaires off.

Construction

The sensor is made up of the following components:
• Light sensor (A)
• Motion sensor (B)
• Housing (C)
• Connections (D) for signal line, zero line and phase

Installation

Safety instructions

The sensor must only be installed and put into operation by

a qualified electrician. The applicable safety regulations and

accident prevention regulations must be observed.

WARNING!
Exposed, live cables or damaged housing.
Danger of electric shock!
• Only work on the sensor when it is de-

energized.

• Disconnect the sensor or luminaire from the

power supply if the housing or plastic lens is

damaged.

CAUTION!

Destruction of the sensor and other devices

through incorrect mounting!
• Only use electronic OSRAM ballast coils of the

type QUICKTRONIC INTELLIGENT DALI (QTi

DALI…DIM), HALOTRONIC INTELLIGENT

DALI (HTi DALI…DIM) or OPTOTRONIC

INTELLIGENT DALI (OT…DIM).

• Do not operate any other other control units on

the control line.

• Do not exceed the maximum number of

ballast coils and maximum overall cable length

between the operating button, sensor and

ballast coil.

• Do not connect control line with external

voltage.

• Only supply sensor with an AC operating vol-

tage, especially in networks with UPS systems.

Connecting the sensor

E Operating pushbutton: Same phase as sensor.
F Electronic ballast coil (EVG): Connect max. 4 ballast coils.
G Signal line: Max. 10 m.
H Sensor: Cable connection via 3-wires permitted for mains

voltage. Do not switch the sensors in parallel.

Light and motion sensor

Fitting instructions

Continued on the back page!