Technical data

Operating voltage

10 … 24 V

DC

Output current per channel

350 mA

Output load range per channel

0 … 8 W at 24 V

DC

Max. power loss

2.22 W

Max. voltage drop (V

in

– V

out

)

0.55 V

Resolution

8 bits

DMX protocol

DMX512-A standard

Max. line cross-section

(for connecting power supply and LED

outputs)

0.5 … 1.5 mm

2

Input reverse polarity protection

Yes

Output short circuit protection

Yes

Operating temperature

-20 °C … +50 °C

Protection type

IP 20

Weight

0.040 kg

Dimensions (L x W x H)

118 x 30 x 21 mm

Setting the DMX addresses

To be able to individually control the three LED outputs in a

DMX network, the dimmer is assigned three consecutive DMX

addresses (default setting: 1, 2 and 3), depending on the

particular application. Follow the operating instructions of the

control unit.
The DMX address for LED output 1 (= DMX start address)

can be set manually (default setting = 1). The following DMX

addresses are automatically assigned to LED outputs 2 and 3

(default setting: 2 and 3). Proceed as follows to set a different

DMX start address:
Note: The DMX start address can be set up globally for multiple

devices by connecting several OT DMX 3x350 DIM LI to the

same DMX network and performing the following procedure.



Connect the dimmer to the control unit and switch on both.

‚

Set all DMX channel values to 0 (e.g. by using the sliders at

the DMX mixing desk).

ƒ

Press pushbutton (C) for at least 1 s. The “DMX” LED

flashes. The dimmer starts to listen and waits for a DMX

configuration data frame (there is no timeout). If necessary,

press pushbutton (C) for less than 1 s to abort listening

mode.

„

Set one DMX channel (e.g. channel 3) to a value greater

than zero. The DMX start address associated to LED output

1 will be set to 3. The consecutive DMX addresses (chan-

nels 4 and 5) are automatically associated with LED outputs

2 and 3. The “DMX” LED stops flashing after the assignment

is made.

Reset the DMX start address to 1



Press pushbutton (C) for at least 1 s. The “DMX” LED

flashes.

‚

Press pushbutton (C) again for at least 1 s. The “DMX” LED

goes out.

The DMX start address of the dimmer is reset to 1.

Operation

Installation (cont.)

Appendix

Connecting the DMX components

Control unit (OSRAM EASY DMX SO or equivalent):

“DMX In” (B)
Optionally, up to 32 dimmers (depending on cable length and

cable quality) can be connected in a row without DMX signal

repeater.

1

2

3

4

> 1 s

1

DMX

Address

Setting

DMX

2

3

4

5 …

1

2

3

4

5

LED output 3

LED output 2

LED output 1

The CE requirements as per EN 55015, EN 61547 and

EN 61347 are fulfilled.

Conformity with the relevant EU directives is

confirmed by the CE symbol.

Advertising