La-610 rear chassis – Universal Audio LA-610 Channel Strip User Manual

Page 11

Advertising
background image

6

Meter Calibration

The 0dB gain reduction reading may need to be calibrated using the GR Zero Set pot.
The GR Zero Set pot is located through a small hole on the front panel below the UA
diamond logo.

1) Turn the LA-610 on and warm up for 5 minutes.
2) Set the meter knob to the GR position.
3) With the Compressor section (right side) Peal Reduction control full off (CCW) adjust
the GR Zero Set trim pot so the meter reads 0 dB. Turn pot slowly and watch how meter
settles.

LA-610 Rear Chassis

On the left, AC Power input with fuse holder.

On the right, the LA-610 MIC INPUT, LINE INPUT, and LINE OUTPUT XLR
connectors. These connectors are discussed in the following sections.

MIC

INPUT

LINE

OUTPUT

LINE

INPUT

POWER IN:

115V ~ 50/60Hz 400ma

230V ~ 50/60Hz 200ma

FUSE RATING:

T 400ma L 115V~

T 200ma L 230V~

REPLACE FUSE WITH SAME

RATING AND TYPE ONLY!

CAUTION / AVIS

RISK OF ELECTRIC SHOCK

DO NOT OPEN

RISQUE DE CHOC ELECTRIQUE

NE PAS OUVRIR

!

CAUTION: TO REDUCE THE RISK OF FIRE OR

ELECTRICAL SHOCK DO NOT EXPOSE THIS

PRODUCT TO RAIN OR MOISTURE

ATTENTION: POUR REDUIRE LE RISQUE DU FEU

OU DE CHOC ELECTRIQUE N'EXPOSEZ PAS CE

PRODUIT A LA PLUIE OU A L'CHUMIDITE'

CE

UNIVERSAL AUDIO, INC

SANTA CRUZ, CALIF. USA

Figure 3: LA-610 Rear Chassis

Input/Output
Standard XLR input and output connectors are provided on the rear panel. Pin 2 is wired
positive (hot) on the LINE and MIC INPUTS. Pin 2 is positive on the LINE OUTPUT
when the front panel Polarity toggle switch is down (IN ). Pin 3 is positive on the LINE
OUTPUT when the front panel Polarity switch is up (OUT ).

AC Power
The LA-610 uses a standard, detachable IEC power cable.

Fuse/Mains
The AC power fuse is located in the AC power connector block. Remove the power cord
before checking or changing the fuse.