Procom LPZ 960 User Manual

Lpz 960

Advertising
background image

LPZ 960

Coaxial Low-Pass Filter for the 900 MHz Band

DESCRIPTION

Passes all signals in or below the 900 MHz band.
Rejects signals above this range.
Absolute stop band from 1640 MHz to 6 GHz

- no degradation at harmonics (Zolotarev-characteristic).
Attenuation in stop band better than 60 dB.
Insertion loss in pass range less than 0.4 dB.
Provided with brackets for panel mounting.

ORDERING DESIGNATIONS

TYPE

PRODUCT NO.

LPZ 960

200001291

SPECIFICATIONS

ELECTRICAL

MODEL

LPZ 960

FILTER TYPE

Low-pass filter for the 900 MHz band

FREQUENCY

Pass band: 820 - 960 MHz

Stop band: 1.64 - 6 GHz

MAX. INPUT POWER

150 W

INSERTION LOSS (PASS BAND)

≤ 0.4 dB

1 dB CUT-OFF FREQUENCY

> 970 MHz

ATTENUATION (STOP BAND)

> 60 dB

MECHANICAL

TEMP. RANGE

–30° C → +80° C

CONNECTORS

N-female

DIMENSIONS (L x W x H)

165 x 40 x 36 mm

WEIGHT

Approx. 240 g

TYPICAL RESPONSE CURVES

The LPZ 960 is used to prevent RFI (Radio Frequency Interference) caused

by excessive harmonicgeneration from transmitters operating in the 900

MHz band. By rejection, the filter reduces the amplitude of the harmonics

and prevents them from being radiated by the antenna.
The filter is normally used in connection with base station transmitters, but

as it is mechanically very ruggedly designed, it is perfectly suited for mobile

and marine applications as well.

PROCOM A/S reserve the right to amend specifications

without prior notice.