Procom LP 175 User Manual

Lp 175

Advertising
background image

LP 175

Low-Pass Filter for the 160 MHz Band

DESCRIPTION

The LP 175 is a low-pass filter, which passes all signals in or below the 2

m-band (138 - 175 MHz), and rejects signals above this range.
The LP 175 is used to prevent RFI (Radio Frequency Interference)

caused by excessive harmonic-generation from transmitters operating in

the 2 m band. By rejection, the filter reduces the amplitude of the

harmonics and prevents them from being radiated by the antenna.
The LP 175 has a very sharp rolloff between the passband and the

stopband while at the same time keeping a low ripple in the passband.
The use of extremely high-Q resonant circuits ensures, that all of the

attenuation is due to reflection and not dissipation, resulting in

extraordinary low insertion loss and high power-handling capability.
The filter is normally used in connection with base station transmitters,

but as it is mechanically very ruggedly designed, it is also perfectly

suited for mobile and marine applications as well.
Materials used are brass and passivated steel, and the filter is black vinyl

coated to prevent corrosion.

ORDERING DESIGNATIONS

TYPE

PRODUCT NO.

LP 175

200001274

SPECIFICATIONS

ELECTRICAL

MODEL

LP 175

APPLICATION

Low-pass filter for the 2 m band

FREQUENCY

Pass band: 0 – 175 MHz

(nominal): 138 - 175 MHz

Stop band: 300 - 1400 MHz

MAX. INPUT POWER

150 W

INSERTION LOSS (PASS BAND)

≤ 0.5 dB

1 dB CUT-OFF FREQUENCY

> 180 MHz

ATTENUATION 270 - 320 MHz

> 50 dB

ATTENUATION 321 - 360 MHz

> 70 dB

ATTENUATION 361 - 1100 MHz

> 90 dB

ATTENUATION 1101 - 1400 MHz

> 60 dB

MECHANICAL

TEMP. RANGE

–30° C → +60° C

CONNECTORS

N-female

DIMENSIONS (L x W x H)

155 x 72 x 52 mm

WEIGHT

Approx. 410 g

MOUNTING DETAILS

TYPICAL RESPONSE CURVES

PROCOM A/S reserve the right to amend specifications

without prior notice.
25/10/12

Advertising