Procom BPBR 2-...-125 User Manual

Bpbr 2

Advertising
background image

BPBR 2/...-125

Band-Pass/Band-Reject Filters for the 150 MHz Band

DESCRIPTION

High power base station band-pass/band-reject filters for the 140 – 175

MHz range.
The use of large ø125 mm cavities means a high Q, resulting

in a very narrow pass/reject spacing.
The large dimensions also mean a high power rating.
Unloaded Q of a single cavity is approx. 4500.
High frequency stability on temperature and power.
Mounted on 19” brackets.**

ORDERING DESIGNATIONS

TYPE

PRODUCT NO.

BPBR 2/1-125

200001081

BPBR 2/2-125

200000959

BPBR 2/3-125

200001909

SPECIFICATIONS

ELECTRICAL

MODEL

BPBR 2/1-125

BPBR 2/2-125

BPBR 2/3-125

FREQ. RANGE

140 - 175 MHz

140 - 175 MHz

140 - 175 MHz

MAX. INPUT

POWER

250 W

250 W

250 W

INSERTION LOSS

See figure 1

(0.7 dB @

500 kHz)

See figure 2

(1.4 dB @

500 kHz)

See figure 3

(2.1 dB @

500 kHz)

ATTENUATION

See figure 1

See figure 2

See figure 3

IMPEDANCE

Nom. 50 Ω

Nom. 50 Ω

Nom. 50 Ω

SWR

< 1.5

< 1.5

< 1.5

MECHANICAL

TEMP.

RANGE

RH 0-90%

non-condensing

–30° C →

+60° C

–30° C →

+60° C

–30° C →

+60° C

FREQ.

STABILITY

Approx. 1.5

ppm/° C

Approx. 1.5

ppm/° C

Approx. 1.5

ppm/° C

CONNECTORS

N-female

N-female

N-female

DIMENSIONS

ø125 x

600 mm

L:125 x W:285 x

H:600 mm

L:125 x W:425 x

H:600 mm

WEIGHT

Approx.

1.9 kg

Approx.

4 kg

Approx.

6.5 kg

TYPICAL RESPONSE CURVES

Figure 1

TYPICAL RESPONSE CURVES

Figure 2

Figure 3

PROCOM A/S reserve the right to amend specifications

without prior notice.
15/08/11