Operation
The hood is fitted with a control panel with aspiration speed
selection control and a light switch to control cooking area
lights.
Use the high suction speed in cases of concentrated kitchen
vapours. It is recommended that the cooker hood suction is
switched on for 5 minutes prior to cooking and to leave in
operation during cooking and for another 15 minutes
approximately after terminating cooking.

Maintenance
ATTENTION!
Before performing any maintenance operation,
isolate the hood from the electrical supply by switching off at
the connector and removing the connector fuse.
Or if the appliance has been connected through a plug and
socket, then the plug must be removed from the socket.
The cooker hood should be cleaned regularly (at least with the
same frequency with which you carry out maintenance of the
fat filters) internally and externally. Clean using the cloth
dampened with neutral liquid detergent. Do not use abrasive
products. DO NOT USE ALCOHOL!
WARNING: Failure to carry out the basic cleaning
recommendations of the cooker hood and replacement of the
filters may cause fire risks.
Therefore, we recommend observing these instructions.
The manufacturer declines all responsibility for any damage to
the motor or any fire damage linked to inappropriate
maintenance or failure to observe the above safety
recommendations.
Fig. 22

This model is equipped with a perimetric suction panel.

The panel allows to optimize the performances of the

hood.

Attention! Hold the panel with both hands when
dismantling and re-mounting in position to avoid it falling
and causing damage to people or things.

Panel maintenance

Disassembly:

1.

pull out firmly (LOWER SIDE) and rotate upwards.

2. unscrew the safety knob S

3. unhook it from the back hinges.

Cleaning:

The suction panel must be cleaned as frequently as the

grease filter, use a cloth dampened with neutral washing

liquids.

Avoid using products containing abrasives. DO NOT USE

ALCOHOL!

Assembly :

Operate inversely to disassembly.

Attention! always make sure that the panel is well fixed in its

proper place.

Grease filter
Fig. 9-24
The grease filter
must be cleaned once a month using non
aggressive detergents, either by hand or in the dishwasher,
which must be set to a low temperature and a short cycle.
When washed in a dishwasher, the grease filter may discolour
slightly, but this does not affect its filtering capacity.

Charcoal filter (filter version only)
Fig. 23
The charcoal filter can be washed once every two months
using hot water and a suitable detergent, or in a dishwasher at
65°C (if the dishwasher is used, select the full cycle function
and leave dishes out).
Eliminate excess water without damaging the filter, then put it
in the oven for 10 minutes at 100° C to dry completely.
Replace the mattress every 3 years and when the cloth is
damaged.

Replacing lamps
Fig. 25
Disconnect the hood from the electricity.
Warning! Prior to touching the light bulbs ensure they are
cooled down.
Replace with a new 12 Volt, 20 Watt (Maximum) halogen light
made for a G-4 base SUITABLE FOR USE IN OPEN
LUMINAIRES. Follow package directions and do not touch
new light with bare hands.