Electrical specifications, General specifications, Austin lynx – GE Industrial Solutions Austin Lynx 24V User Manual

Page 4: Continued)

Advertising
background image

Data Sheet
September 10, 2013

Austin Lynx

TM

24V: Non-isolated Power Modules:

18/20– 30/32Vdc input; 3 – 6Vdc & 5 – 15Vdc Output; 30/50W

LINEAGE

POWER

4

Electrical Specifications

(continued)

Parameter

Device

Symbol

Min

Typ

Max

Unit

Dynamic Load Response

(dI

O

/dt=5A/

μs; V

IN

=V

IN

,

nom

T

A

=25°C)

Load Change from Io= 50% to 100% of I

O

,max; No

external output capacitors

Peak Deviation (Vo

= 3.3Vdc)

AXB030

V

pk

300 mV

Peak Deviation (Vo

= 12Vdc)

AXB050

V

pk

220 mV

Settling Time (V

O

<10% peak deviation)

All t

s

50

μs

(dI

O

/dt=5A/

μs; V

IN

=V

IN

,

nom

; T

A

=25°C)

Load Change from I

O

= 100% to 50%of I

O

,

max

: No

external output capacitors

Peak Deviation (Vo

= 3.3Vdc)

AXB030

V

pk

320 mV

Peak Deviation (Vo

= 12Vdc)

AXB050

V

pk

220 mV

Settling Time (V

O

<10% peak deviation)

All t

s

50

μs

(dI

O

/dt=5A/

μs; V

IN

=V

IN

,

nom

; T

A

=25°C)

Load Change from Io= 50% to 100% of Io,max;
2x150 μF polymer capacitor

Peak Deviation (Vo

= 3.3Vdc)

AXB030

V

pk

120 mV

Peak Deviation (Vo

= 12Vdc)

AXB050

V

pk

130 mV

Settling Time (V

O

<10% peak deviation)

All t

s

50

μs

(dI

O

/dt=5A/

μs; V

IN

=V

IN

,

nom

; T

A

=25°C)

Load Change from Io= 100% to 50%of I

O,max

:

2x150 μF polymer capacitor

Peak Deviation (Vo

= 3.3Vdc)

AXB030

V

pk

130 mV

Peak Deviation (Vo

= 12Vdc)

AXB050

V

pk

130 mV

Settling Time (V

O

<10% peak deviation)

All t

s

50

μs

General Specifications

Parameter

Device

Min

Typ

Max

Unit

Calculated MTBF (V

IN

= V

IN, nom

, I

O

= 0.8I

O, max

,

T

A

=40°C) Telecordia SR 332 Issue 1: Method 1,

case 3

AXB050 8,035,510

Hours

Weight

5.70 (0.20)

g (oz.)




Advertising