Emc considerations, Lineage power 12 – GE Industrial Solutions EHW007A0B Series (Eighth-Brick) User Manual

Page 12

Advertising
background image

Data Sheet

October 2, 2009

EHW007A0B Series Eighth-Brick Power Modules

36–75Vdc Input; 12.0Vdc Output; 7A Output Current

LINEAGE

POWER

12

EMC Considerations

The circuit and plots in Figure 21 shows a suggested configuration to meet the conducted emission limits of EN55022
Class B.

0

10

20

30

40

50

60

70

80

Level [dBµV]

150k

300k

500k

1M

2M

3M

4M 5M

7M

10M

30M

Frequency [Hz]

x

x

x

xx

x

x x

MES CE0508091459_fin QP
MES CE0508091459_pre PK

0

10

20

30

40

50

60

70

80

Level [dBµV]

150k

300k

500k

1M

2M

3M

4M 5M

7M

10M

30M

Frequency [Hz]

+

+

+

++

+

+ +

MES CE0508091459_fin AV
MES CE0508091459_pre AV

Figure 21. EMC Considerations