. Position the mechanical operations counter (Fig

2.) over the two holes provided inside the
mechanism bracket, ensuring the indicator face is
aligned to show through the window in the cover.

C

B

A

Figure 4. Operations Counter Location

A) Spring charging link B) Operating arm C) Operations

Counter


6. To Reinstall the cover, rotate the charging

handle down and slide the front cover over the
handle to assemble the front cover to housing as
shown in Fig. 5.

Figure 2.

4.

Mount in position using the screws provided

and apply torque 2.5-3Nm (1.84-2.21 ft-lbs).

Figure 5.

7. Ensure the fascia is aligned properly with the

trip unit and the pad lock features of the breaker.

Figure 3.

5. Ensure the operating arm (B) on the counter

8

.

Fasten the 6 mounting screws of fascia with

the housing using a pozidrive screwdriver. Apply
torque of 6 Nm (4.42 ft-lbs).

rides over the spring charging link (A) of the
circuit breaker mechanism (Fig.4).