Emc considerations, Layout considerations – GE Industrial Solutions EQW012-020-023-025 Series User Manual

Page 16

Advertising
background image

Data Sheet

October 5, 2013

EQW012/020/023/025 Series, Eighth-Brick Power Modules:

36 - 75Vdc Input; 1.2Vdc to 5Vdc Output; 12A to 25A Output

LINEAGE

POWER

16

EMC Considerations

The figure 44 shows a suggested configuration to
meet the conducted emission limits of EN55022 Class
B.

Vin+

EQW

Vin-

Vout+

Vout-

LC1

Cim

CX1

CX4

CX2

CX3

Ld1

CX5

CY1

CY2

Figure 44. Suggested Input Filter Configuration
for EN55022 Class B.

Filter components:
Cx1: 47uF aluminum electrolytic, 100V (Nichicon PW series)
Cx2: 2x1uF ceramic, 100V (TDK C4532X7R2A105M)
Cx3: 2x1uF ceramic, 100V (TDK C4532X7R2A105M)
Cx4: 2x1uF ceramic, 100V (TDK C4532X7R2A105M)
Cx5: 100uF aluminum electrolytic, 100V (Nichicon PW
series)
Cy3, Cy4: 3300pF ceramic, 1500V (AVX
1812SC332MAT1A)
Cim: 3300pF ceramic, 1500V (AVX 1812SC332MAT1A)
Lc1: 768 uH, 4.7A (Pulse Engineering P0422)
Ld1: 4.7 uH, 5.5A (Vishay IHLP-2525CZ)

0

10

20

30

40

50

60

70

80

Level [dBµV]

150k

300k

500k

1M

2M

3M

4M 5M

7M

10M

30M

Frequency [Hz]

+

EN55022 Class B Conducted Average dBuV

Figure 45. EMC signature using recommended
filter.

For further information on designing for EMC
compliance, please refer to the FLTR100V10 data
sheet (FDS01-043EPS).




Layout Considerations

Copper paths must not be routed beneath the power
module mounting inserts. Recommended SMT layout
shown in the mechanical section are for reference
only. SMT layout depends on the end PCB
configuration and the location of the load. For
additional layout guide-lines, refer to FLTR100V10
data sheet or contact your local Lineage Power field
application engineer.







Advertising