GE Industrial Solutions AF-650 GP Top & Bottom Cover Duct Kit User Manual

GE Industrial Solutions Equipment

Advertising
background image

This instruction sheet is for the installation of top and bottom covers for the 4x- and 5x-Frame AF-6

drives. These kits are designed to be used to direct the back-channel airflow in and out the back of the

drive as opposed to in the bottom and out the top of the drive (when the drives are being mounted di-

rectly on a wall or inside a welded enclosure).

Using these kits as described removes 85% of the losses via the back channel using the drive’s main

heat sink fan. The remaining 15% must be removed via the door of the enclosure. (Refer to Note 2 for

air flow requirements.)

INSTRUCTIONS

INSTALLATION OF TOP AND BOTTOM COVERS FOR 4x- and 5x-FRAME AF-6

DRIVES INTO WELDED ENCLOSURES

Instruction

No:

177R0110

V1

May

7,

2009

Page

1

Kit Contents

Top and bottom cover plates

Sealing plates

Gaskets

Mounting hardware

Required Tools

Metric Socket Set, 7-19mm

Socket Extensions

Torx Driver Set T10-T40

Torque Wrench 6-50 in-lbs (.7-6 N-M)

Used with:

AF-600FP & AF-650GP

4x

OPCDUCT4344TB

5x

OPCDUCT52TB

OPCDUCT4142TB

OPCDUCT51TB

Unit
Sizes

IP00 /

Chassis

IP21 / NEMA1

IP54 / NEMA12

Torque Requirements

1. M5 screws/nuts torque to 20 in-lbs (2.3 N-M)

2. M6 screws/nuts torque to 35 in-lbs ( 3.9 N-M)

3. M10 nuts torque to 170 in-lbs (20 N-M)

4. T25 Torx screws torque to 20 in-lbs (2.3 N-M)

Notes:

1. If external duct work is added to the exhaust path of the drive, additional back pressure will be cre-

ated that will reduce the cooling of the drive. The drive must be derated to accommodate the re-

duced cooling. First, the pressure drop must be calculated, then refer to the derating tables located

in the AF-6 High Power Operating Instructions.

2. A doorfan(s) is required on the enclosure to remove the heat losses not contained in the backchan-

nel of the drive. The minimum airflow required (at the maximum rated ambient temperature) for the

43 and 44 frame drives is 391 m

3

/h (230 cfm). The minimum airflow required (at the maximum rated

ambient temperature) for the 52 frame drive is 782 m

3

/h (460 cfm). If additional heat losses are

added within the enclosure a calculation must be made to ensure the proper airflow is provided to