Dwg. No. DEH40118

GE Industrial Systems




Material: Adhesive backed white label stock

Size: 2.8 x 4.3 inches

Artwork Available: DEH40118 R3.PDF

TEST INSTRUCTIONS – 1 POLE ARC FAULT

IM PORTANT: HOM EOWNER SHOULD TEST BREAKER M ONTHLY.

ATTACH THIS LABEL TO INSIDE OF PANEL

2.

Arc Test: Rotate the test sw itch in “Arc Test” direction to
check the ability of the breaker to detect arcing from phase to
neutral (above normal levels needed to run appliances) .

3.

Short Test: Rotate test sw itch in “Short Test” direction to
check ability of the breaker to detect low -level arcs from
phase to ground.

:

If arc fault circuit breaker trips unexpectedly:
1. Reset the breaker using instructions above.
2. If tripping continues, a hazardous condition could exist and the
circuit should be inspected by a qualified electrician (for
complete information, see instruction sheet DEH- 40117.

CAUTION: THE ARC FAULT CIRCUIT BREAKER M UST
BE SUPPLIED W ITH POWER FROM THE LOAD CENTER
DURING TEST. IF THE POWER IS ON AND EITHER OF
THESE FAIL TO TRIP, THE CIRCUIT BREAKER M AY BE
UNABLE TO DETECT ARCS. THE CIRCUIT BREAKER IS
DEFECTIVE AND SHOULD BE REPLACED.

ARC TES

SHOR T TES

15 A

TRIP
FLAG

ROCKER

SWITCH

1.

Turn on pow er to load center or panelboard.

4.

Breaker is functioning properly w hen circuit is interrupted,
handle moves to “TRIP” and “TRIP” flag appears in w indow .

5.

Reset the breaker by moving the handle to
the “OFF” position then to the “ON” position.

YEAR

JAN

FEB

M AR

APR

M AY

JUN

JUL

AUG

SEP

OCT

NOV

DEC