11. Reattach the dead front to the interior with the 8 screws removed in step 2.

Tighten the screws to 27-36 in-lb.

Figure 3. Attaching the shield insert to the shield for FB breaker installation in A-Series

®

II Panelboards.

12. If FB breaker has to be installed after SG or SF/TFJ or SE/TED/TQD as shown in

Figure 4 then gap between the breakers (dim A) has to be followed as mentioned
in Table 2. Replace the subsequent blank filler of dead front with FB filler plate
given in kit using steps 9 to 11.

13. If FB breaker has to installed immediate after crossbar as shown in Figure 5 then

gap between the breaker and crossbar has to be 0.0575inch.