Feature descriptions – GE Industrial Solutions Austin Minilynx SIP User Manual

Page 13

Advertising
background image

Data Sheet
October 2, 2009

Austin MiniLynx

TM

SIP Non-isolated Power Modules:

2.4 – 5.5Vdc input; 0.75Vdc to 3.63Vdc Output; 3A output current


LINEAGE

POWER

13

Feature Descriptions

(continued)

Output Voltage Programming

The output voltage of the Austin MiniLynx

TM

SIP can be

programmed to any voltage from 0.75 Vdc to 3.63 Vdc
by connecting a single resistor (shown as Rtrim in
Figure 32) between the TRIM and GND pins of the
module. Without an external resistor between TRIM pin
and the ground, the output voltage of the module is
0.7525 Vdc. To calculate the value of the resistor Rtrim
for a particular output voltage Vo, use the following
equation:

Ω

⎥⎦

⎢⎣

=

5110

7525

.

0

21070

Vo

Rtrim


For example, to program the output voltage of the
Austin MiniLynx

TM

module to 1.8 Vdc, Rtrim is calculated

is follows:

⎥⎦

⎢⎣

=

5110

7525

.

0

8

.

1

21070

Rtrim

Ω

=

k

Rtrim

004

.

15

V

O

(+)

TRIM

GND

R

trim

LOAD

V

IN

(+)

ON/OFF

Figure 32. Circuit configuration to program output
voltage using an external resistor.

Table 1 provides Rtrim values required for some
common output voltages.

Table 1

V

O, set

(V)

Rtrim (KΩ)

0.7525 Open

1.2 41.973
1.5 23.077
1.8 15.004
2.5 6.947
3.3 3.160


By using a 1% tolerance trim resistor, set point
tolerance of ±2% is achieved as specified in the
electrical specification. The POL Programming Tool,
available at

www.lineagepower.com

under the Design

Tools section, helps determine the required external
trim resistor needed for a specific output voltage.

Voltage Margining

Output voltage margining can be implemented in the
Austin MiniLynx

TM

modules by connecting a resistor,

R

margin-up

, from the Trim pin to the ground pin for

margining-up the output voltage and by connecting a
resistor, R

margin-down

, from the Trim pin to the Output pin

for margining-down. Figure 33 shows the circuit
configuration for output voltage margining. The POL
Programming Tool, available at

ww.lineagepower.com

under the Design Tools section, also calculates the
values of R

margin-up

and R

margin-down

for a specific output

voltage and % margin. Please consult your local
Lineage Power technical representative for additional
details.

Vo

Austin Lynx or
Lynx II Series

GND

Trim

Q1

Rtrim

Rmargin-up

Q2

Rmargin-down

Figure 33. Circuit Configuration for margining
Output voltage.

Advertising