7
Data Sheet
March 2008
75 Vdc Input Maximum, 10 A Maximum
FLTR100V10 Filter Module
Application
(continued)
8-1362a
Note: C1 through C4 and C6 through C9 can be 0.01 µF to 0.1 µF. Select the voltage rating to meet input-to-output isolation requirements.
C5 should be the recommended value indicated in the power module data sheet.
Figure 8. Recommended Schematic of Filter Module with Two Power Modules
C1
V
I
(+)
V
I
(-)
V
O
(+)
V
O
(-)
GND
FILTER
MODULE
C2
C5
V
I1
(-)
V
I1
(+)
CASE 1
V
O1
(-)
V
O1
(+)
C3
C4
POWER MODULE 1
SHIELD PLANE
Vdc INPUT(+)
Vdc INPUT(-)
CHASSIS GROUND
C6
V
I2
(-)
V
I2
(+)
CASE 2
V
O2
(-)
V
O2
(+)
C8
C9
POWER MODULE 2
C7
SHIELD PLANE