Features:

by Lineage Power

www.LineagePower.com

Lineage Power

Lineage Power

Lineage Power (China)

3000 Skyline Dr.

2841 Dow Avenue

1353 Chenqiao Road, Shanghai Sengpu Industrial Park

Mesquite, TX 75149

Tustin, CA 92780 USA

Shanghai, 201401 China

Phone: (972) 284-2000

Phone: (714) 544-6665

Phone: 021 6710 8910

75 Watt Modular Power Supply

Universal AC Input Range (90-264 VAC)

Optional Power Factor Correction (CCH Models)

Low Profile for 1U High Applications

Meets VDE/FCC Class “B” EMI

Industry Standard 3 x 5” Footprint

Total Power Overload Limit Protection

Over-Current Protection

International Safety Certifications - UL, CSA, TUV & CE Mark (LVD)

KEY MARKET SEGMENTS & APPLICATIONS

Automation Equipment

Test Equipment

Industrial Applications

POS Equipment

Computer Peripherals

Gaming

Networking / Datacom

SPECIFICATIONS

75 Wat Switching Power Supply

Input Voltage Range

Universal AC Input Range (90-264 VAC, 47-63 Hz

Input Current Maximum

1.25A (max continuous, 85VAC Full Load)

Inrush Current

20A @ 115 VAC / 32A @ 230 VAC (typical)

Input Protection

Single fuse (2.0 or 3.5A / 250VAC / HB Type)

Power Factor

Passive PFC for EN61000-3-2 Class D Compliance

Efficiency

70% typical (65% minimum) @ 115 VAC (measured at full load)

EMI

FCC and VDE Level “B” (Conducted)

Output Power

75 Watts Continuous

Over-Power Limit

Set at 90W typical by sensing the primary input current

Over-Load Protection

V1 & V2 of CCH74 Models / V1 of CCH75 Models only. 110 - 135% of max Iout. Output recovers when fault is removed

Over-Voltage Protection

V1 & V2 of CCH74Models / V1 of CCH75Models only. Trip point set at 116%- 130%of V1 or V2. To reset, cycle input power

Voltage Adjustment Range

±5% of V1 only, V2 / V3 is fixed

Regulation

±2% max of V1, V2 / V3 is ±5% max

Ripple & Noise

1% pk-pk maximum @ 20MHz

Operating Temperature

Full load from 0 to 50ºC. Derates linearly from 50ºC to 70ºC at 2.5% per ºC, 8 CFM Required for Full Power

Shock & Vibration

Per MIL STD-810E per 516.4 Part IV

Dimensions

3.00 x 5.00 x 1.95” (76.2mm x 125.7mm x 38.1mm) for standard open frame model

Safety Approvals

UL 1950, CSA 22.2 No. 950 & 234, TUV (EN60950), CE Mark & CB Report

FEATURES

BENEFITS

PFC Compliant to EN61000-3-2

Supports global use of power supply

Input Protection per EN61000-4

Designed to operate in harsh environmental conditions

Economical

Lowered system costs

Flexibility With Options

Custom capability without NRE & long lead-times

CCH Series

75 Watt Swithing Power Supply

rev 091201

MODEL

V1 OUTPUT

V2 OUTPUT

V3 OUTPUT

Vout

Io Min

Io Max

Io Peak

Vout

Io Min

Io Max

Io Peak

Vout

Io Min

Io Max

Io Peak

CCH75F1

12

0 .60

6.25

8.00

CCH74C3

+3.3

0.60

9.00

10.00

+5.1

0.40

N/S

3.50

+5

0.10

1.00

N/S

CCH74D3

+3.3

0.90

9.00

10.00

+5.1

0.20

N/S

2.00

+12

0.10

1.00

N/S

CCH74H3

+5.1

0.90

9.00

10.00

+3.3

0.20

N/S

3.50

+12

0.10

1.00

N/S

CCH75K3

+5.1

0.90

9.00

10.00

+12

0.30

3.00

3.50

-12

0.10

1.00

1.50

CCH75Q3

+5.1

0.90

9.00

10.00

+15

0.30

3.00

3.50

-15

0.10

1.00

1.50

Advertising