GE Industrial Solutions Spectra RMS Cable Operators User Manual

Page 2

Advertising
background image

Cable Operated Interface Mechanism installation To Enclosure Door

1. Assemble GEPC rotary handle to the enclosure door through the holes as per the instructions given in GEPC rotary

handle instruction sheet.

2. Locate and orient the moving arm assembly on the base plate assembly diameter 0.25 hole as shown in the Figures

1, Figure 4, and Figure 5.

3. Assemble the GEPC rotary handle shaft one end with (driver part) moving arm assembly as shown in Figure1 and

assemble the other end of the shaft to the rotary handle. (Keep the rotary handle in off position while doing the
shaft assembly and follow the GEPC rotary handle instruction sheet for more details on shaft assembly).

4. Position the cable operated interface mechanism below the enclosure door and locate with the drilled holes as per

the Figure 3.

5. Place and locate the spacer (item1), with base plate assembly holes of ¼ inch diameter & holes in enclosure door.
6. Install the cable-operated mechanism to the enclosure door with #12-24 screws (item 2 and item 8), nuts (item 3) &

washers (item 4). Tighten the screws to 30-35 in-lb.

7. Refer Table 5 for hardware details.

Figure 1. Cable Operated Interface

Mechanism Installation to Enclosure Door.

2

The location of the enclosure face mounted SCRM
mechanism/handle with respect to the circuit breaker
mounting location is

NOT fixed. The only requirements

that must be met are:
1) The cable is long enough to reach from the handle

WARNING: Before installing any accessories, turn the breaker off, disconnect it from all voltage sources
and discharge the closing springs.

A VERTISSEMENT: Avant d’installer tout accessoire, mettre le disjoncteur en position OFF, le
d’econnecter de toute tension d’alimentation, et d’echarger les resorts d’armement.

Advertising