Electrical specifications, General specifications, Austin superlynx – GE Industrial Solutions Austin SuperLynx II 12V SIP User Manual

Page 4

Advertising
background image

Data Sheet
October 1, 2009

Austin SuperLynx

TM

II

12V SIP Non-isolated Power Modules:

8.3 – 14Vdc input; 0.75Vdc to 5.5Vdc Output;16A output current

LINEAGE

POWER

4

Electrical Specifications

(continued)

Parameter

Device

Symbol

Min

Typ

Max

Unit

Dynamic

Load

Response

(dIo/dt=2.5A/

μs; V V

IN

= V

IN, nom

; T

A

=25°C)

All V

pk

100

mV

Load Change from Io= 50% to 100% of Io,max;
Co = 2x150 μF polymer capacitors

Peak Deviation

Settling Time (Vo<10% peak deviation)

All t

s

50

μs

(dIo/dt=2.5A/

μs; V

IN

= V

IN, nom

; T

A

=25°C)

All V

pk

100

mV

Load Change from Io= 100% to 50%of Io,max:
Co = 2x150 μF polymer capacitors

Peak Deviation

Settling Time (Vo<10% peak deviation)

All t

s

50

μs

General Specifications

Parameter

Min

Typ

Max

Unit

Calculated MTBF (I

O

=I

O, max

, T

A

=25°C) 9,230,550

Hours

Telecordia SR-332 Issue 1: Method 1 Case 3

Weight

5.6 (0.2)

g (oz.)