Electrical specifications (continued), Isolation specifications, General specifications – GE Industrial Solutions EHW015A0A Series (Eighth-Brick) User Manual

Page 3

Advertising
background image

Data Sheet

October 2, 2009

EHW015A0A Series Eighth-Brick Power Modules

36–75Vdc Input; 5.0Vdc Output; 15A Output Current

LINEAGE

POWER

3

Electrical Specifications

(continued)

Parameter

Device

Symbol

Min

Typ

Max

Unit

Nominal Output Voltage Set-point

V

IN

=V

IN, min

, I

O

=I

O, max

, T

A

=25°C) All

V

O, set

4.90 5.0 5.10 V

dc

Output Voltage

(Over all operating input voltage, resistive load, and
temperature conditions until end of life)

All

V

O

4.85

5.15 %

V

O, set

Output Regulation

Line (V

IN

=V

IN, min

to V

IN, max

) All

±0.2 %

V

O, set

Load (I

O

=I

O, min

to I

O, max

)

All

⎯ ±0.2

%

V

O, set

Temperature (T

ref

=T

A, min

to T

A, max

) All

±0.2

% V

O, set

Output Ripple and Noise on nominal output

(V

IN

=V

IN, nom

,I

O

= I

O, max

, T

A

=T

A, min

to T

A, max

)

RMS (5Hz to 20MHz bandwidth)

All

15 25 mV

rms

Peak-to-Peak (5Hz to 20MHz bandwidth)

All

40 75

mV

pk-pk

External Capacitance

All

C

O

500

4,700

μF

Output Current

All

I

O

0

15 A

dc

Output Current Limit Inception (Hiccup Mode )
(V

O

= 90% of V

O, set

)

All

I

O, lim

105 120 130 % I

o

Output Short-Circuit Current

(V

O

≤250mV) ( Hiccup Mode )

All I

O, s/c

5 A

rms

Efficiency

V

IN

= V

IN, nom

, T

A

=25°C, I

O

=I

O, max ,

V

O

= V

O,set

All

η 92.0 %

V

IN

= V

IN, nom

, T

A

=25°C, I

O

=0.5I

O, max ,

V

O

= V

O,set

All

η 90.0 %

Switching Frequency

All

f

sw

400 kHz

Dynamic Load Response

(dI

o

/dt=0.1A/

μs; V

IN

= V

IN, nom

; T

A

=25°C, C

o

=C

o,min

)

Load Change from Io= 50% to 75% or 25% to 50% of
I

o,max

Peak Deviation

All

V

pk

2

% V

O, set

Settling Time (Vo<10% peak deviation)

All t

s

200

μs

(dI

o

/dt=1.0A/

μs; V

IN

= V

IN, nom

; T

A

=25°C, C

o

=C

o,min

)

Load Change from Io= 50% to 75% or 25% to 50% of
I

o,max

Peak Deviation

All

V

pk

2

% V

O, set

Settling Time (V

o

<10% peak deviation)

All t

s

200

μs

Isolation Specifications

Parameter

Device

Symbol

Min

Typ

Max

Unit

Isolation Capacitance

All

C

iso

2000

pF

Isolation Resistance

All

R

iso

100

MΩ

I/O Isolation Voltage (100% factory Hi-pot tested)

All

All

2250 V

dc

General Specifications

Parameter

Device

Symbol

Min

Typ

Max

Unit

All FIT

244.1

10

9

/Hours

Calculated Reliability based upon Telcordia SR-332
Issue 2: Method

I

Case 3 (I

O

=80%I

O, max

, T

A

=40°C,

airflow = 200 lfm, 90% confidence)

All MTBF

4,097,359

Hours

Weight (Open Frame)

All

19

(0.67)

g

(oz.)

Weight (with Heatplate)

All

31

(1.09)

g

(oz.)

Advertising