GE Industrial Solutions EntelliGuard G Door Interlock Kit User Manual

Page 2

Advertising
background image


2. Position interlock lever as shown in Fig 3.

3. Position one leg of the spring below the second
pin and position the other leg of the spring over
the interlock bracket.
4. Holding lever in position; insert circlips one
each into the groove in the spring pin & Second

Pin (Fig. 3). Now the interlock swings in the slot
with respect to the pivot pin 1
5. Based on the door interlock type, drill the hole
pattern on the door as shown in fig 3 & 4.

Dimensions shown are in mm (inches)



6. Assemble the door bracket to the door using
the screws and washers as shown in fig 5.

Dia 5.3 (0.209)

Figure 5



7. When the door is closed, the bracket on the

door will be hooked to the door interlock on the
cassette as shown in fig 6.

Figure 6








L.H hinged
Door cut-out

20
(0.79)

F1, 3P – 32.5 (1.28)
F1, 4P – 132.5 (5.22)
F2, 3P – 67.5 (2.66)
F2, 4P – 197.5 (7.78)
F3, 3P – 222.5 (8.76)
F3, 4P – 340.5 (13.4)

198 (7.8)

Fig. 3 (GLHD)

RH hinged
Door cut-out

20 (0.79)

198
(7.8)

F1, 3P & 4P – 33.5 (1.32)
F2, 3P & 4P – 98.5 (3.88)
F3, 3P - 240.5 (9.47)

Dia 5.3 (0.209)

F3, 4P - 355.5 (14.0)

Fig. 4(GRHD)

2