Instructions:

Select a 3 pole Type SEL/SEP Spectra

®

RMS circuit breaker with its ampere rating

equal to or less than the SAXSEL, SAXSEP current limiter’s ampere rating.

CATALOG NUMBER

Ampere
Rating

Add ON Limiter

Interrupting rating
at 600V

For use with circuit
breaker catalog type

150

SAXSEL36150

65,000 (Sym)

SELA36*******

150

SAXSEP36150

100,000 (Sym)

SEPA36*******

Contents of kit:

1.

Qty (1) SAXSEL or SAXSEP current limiter.

2.

Qty (3) 1/4 - 28 X 1/2” screws.

3. Qty (2) 8 –32 X 2-7/8” screws.

CAUTION

1.

When installing accessories, the breaker must be completely deenergized
and disconnected from the electrical circuit.

2. Connect the current limiter on the load end of the circuit breaker.

Assembly Instructions:

1.

Remove lugs (if present) from load end of circuit breaker.

2.

Attach current limiter line terminals to circuit breaker load terminals using (3)
1/4 - 28 screws provided. Torque to 30 – 35 in. lbs (Figure 2)

3.

Attach qty (3) lugs (not provided) to current limiter load terminals.

(Select lugs for limiter from Table 1).

4.

Mount the breaker/limiter assembly into equipment using mounting screw kit
SEMSK1 or SEMSK3 (not provided). Caution: The back surface of the limiter
does not lie in the same plane as the back surface of the breaker (figure 3). If
the mounting surface of the equipment extends in back of the limiter,
accommodate the offset by shimming the breaker or offsetting the mounting
surface. Securing the limiter to the mounting plate is optional - use qty (2) 8 -
32 screws provided (Figure 2 & 3).

NOTES:

1.

SAXSEL/SAXSEP current limiter can be used with 3 pole Type SEL/SEP Spectra

®

RMS motor circuit protector however, the interrupt rating is based on evaluation
as part of a combination motor controller per UL508/845.

2.

If plunger(s) is extended, current limiter must be replaced.

Figure 1


Table1

LUG

AMPACITY

WIRE RANGE

TCAL14

15–30 A

(1) # 14-8 Cu, # 12-8 Al

TCAL12

15–60 A

(1) # 14-3 Cu, # 12-1 Al

TCAL12A

70–90 A

(1) # 6-2/0 Cu, # 4-2/0 Al

TCAL15

100–150 A

(1) # 3-3/0 Cu, # 1-3/0 Al

TCAL18

15–150 A

(1) # 12-3/0 Cu/Al

GE Consumer & Industrial
41 Woodford Avenue, Plainville, CT 06062

www.geelectrical.com

© 2007 General Electric Company

DEH-4671 R01 (11/04)

Back plane
of circuit
breaker

Secure limiter to
the mounting
plate with (2) 8 –
32 screws, if
needed (refer
Figure 3)

Circuit
breaker
load end

Current
limiter
terminals
line end

Current
limiter
terminals
load end

Transfer breaker
lugs to limiter

!

Attach
current
limiter to
circuit
breaker’s
load terminal
with (3) ¼ -
28 screws

These instructions do not cover all details or variations in equipment nor do they provide for every possible contingency that may be met in connection with installation, operation
or maintenance. Should further information be desired or should particular problems arise that are not covered sufficiently for the purchaser’s purposes, the matter should be
referred to the GE Company. The breaker is a sealed unit, which contains no user serviceable parts. Tampering with seal will void warranty.

Figure 2

Back plane
of current
limiter

Figure 3

0.056”

Advertising