Electrical specifications, General specifications, Austin microlynx – GE Industrial Solutions Austin Microlynx SIP User Manual
Page 4
Data Sheet
July 2, 2010
Austin MicroLynx
TM
SIP Non-isolated Power Modules:
3 – 5.5Vdc input; 0.75Vdc to 3.63Vdc Output; 5A output current
LINEAGE
POWER
4
Electrical Specifications
(continued)
Parameter
Device
Symbol
Min
Typ
Max
Unit
Dynamic Load Response
(dIo/dt=2.5A/
μs; V V
IN
= V
IN, nom
; T
A
=25°C)
All V
pk
⎯
50
⎯
mV
Load Change from Io= 50% to 100% of Io,max;
Co = 2x150 μF polymer capacitors
Peak Deviation
Settling Time (Vo<10% peak deviation)
All t
s
⎯
50
⎯
μs
(dIo/dt=2.5A/
μs; V
IN
= V
IN, nom
; T
A
=25°C)
All V
pk
⎯
50
⎯
mV
Load Change from Io= 100% to 50%of Io,max:
Co = 2x150 μF polymer capacitors
Peak Deviation
Settling Time (Vo<10% peak deviation)
All t
s
⎯
50
⎯
μs
General Specifications
Parameter
Min
Typ
Max
Unit
Calculated MTBF (I
O
=I
O, max
, T
A
=25°C) 19,000,000
Hours
Weight
⎯
2.8 (0.1)
⎯
g (oz.)