Electrical specifications (cont.), General specifications, Feature specifications – GE Industrial Solutions CLP0212 User Manual

Page 3: Clp0212 open frame power supply, Preliminary data sheet, Isolation specifications

Advertising
background image

GE

Preliminary Data Sheet

CLP0212 Open Frame Power Supply

90 - 264Vac input; 12Vdc output; 200W Output Power

October 11, 2013

©2012 General Electric Corporation. All rights reserved.

Page 3

Electrical Specifications (cont.)

Parameter

Device

Min

Typ

Max

Unit

Maximum Output Capacitance

All

5000

µF

Standby Output Voltage

CLP0212FPXX5Z01A

CLP0212FPEX5Z01A

5

Vdc

CLP0212FPXX3Z01A

3.3

Vdc

Standby Output Current

All

0.25

Adc

Efficiency: V

IN

= 230Vac, 20% load

All except ..Z02A

86.8

%

50% load

All except ..Z02A

91.1

%

100% load

All except ..Z02A

89.5

%

V

IN

= 115Vac, 20% load

All except ..Z02A

89.2

%

50% load

All except ..Z02A

90.3

%

100% load

All except ..Z02A

87.1

%

Holdup Time – V

IN

= 115Vac, 100% load

2

65W load for CLP0212FPEXZ02A

All except ..Z02A

CLP0212FPEXZ02A

10

45

ms

V

IN

= 230Vac, 100% load

65W load for CLP0212FPEXZ02A

All except ..Z02A

CLP0212FPEXZ02A

10

45

ms

Isolation Specifications

Parameter

Device

Min

Max

Unit

Isolation Voltage – Input to output

All

3000

Vac

Input to safety ground

All

1500

Vac

Outputs to safety ground

All

50

Vac

General Specifications

Parameter

Device

Symbol

Typ.

Unit

Calculated Reliability based on Telcordia SR-332 Issue 2: Method 1 Case

3 (V

IN

=230Vac, I

o

= 16.7A, T

A

= 40ºC, airflow 200LFM, 90% confidence)

All

FIT

MTBF

1,011.9

988,276

10

9

/Hours

Hours

Weight

All

185

6.5

g

oz.

Feature Specifications

Parameter

Device

Min

Typ

Max

Unit

On/Off Signal Interface – signal referenced to GND

Logic Low (Power Supply ON)

Input Low Current

All

7

mA

Input Low Voltage

All

1

V

Logic High (Power Supply OFF)

Input High Current

All

600

µA

Input Voltage

All

5.5

V

Delay from ON/OFF being enabled to start of output voltage rise

All

50

ms

Output Voltage Rise Time (from 10 to 90% of final value)

All

5

ms

Delay from Input being applied to standby output being in regulation

All

12

ms

Delay from Input being applied to all outputs being in regulation

All

30

ms

Output Holdup time (from loss of AC to output being out of regulation)

All

10

ms

Output Overvoltage Protection (for main output currents above 0.1A)

All

13.8

18

Vdc

2

Holdup time is reduced at cold temperatures