March 2008

75 Vdc Input Maximum, 20 A Maximum

FLTR100V20 Filter Module

Application

(continued)

8-1362b

Note: C1 through C4 and C6 through C9 can be 0.01 µF to 0.1 µF. Select the voltage rating to meet input-to-output isolation requirements.

C5 should be the recommended value indicated in the power module data sheet.

Figure 7. Recommended Schematic of Filter Module with Two Power Modules

C1

V

I

(+)

V

I

(-)

V

O

(+)

V

O

(-)

GND

FILTER

MODULE

C2

C5

V

I1

(-)

V

I1

(+)

CASE 1

V

O1

(-)

V

O1

(+)

C3

POWER MODULE 1

SHIELD PLANE

Vdc INPUT(+)

Vdc INPUT(-)

CHASSIS GROUND