Af-650 gp brake resistor design guide – GE Industrial Solutions AF-650 GP General Purpose Drive User Manual

Page 11

Advertising
background image

Horizontal or vertical

movement?

Low or high

inertia?

Low inertia

ramp down >15 sec.

Choose a 10%

duty cycle brake

resistor from the

table*

Horizontal

V

e

rtical

High inertia

ramp down <15 sec.

or don't know

Determine breaking

time of the

application

Compare the braking

time with the resistors

braking period

Braking time <

brake resistor period

Calculate duty

cycle ***

duty cycle < 10%

duty cycle > 40%

duty cycle ranging

from 10-40%

Choose a 10%

duty cycle brake

resistor from the

table*

Choose a 40%

duty cycle brake

resistor from the

table**

Please contact

GEC&I****

Please contact

GEC&I****

Braking time >

brake resistor period

Illustr

atio

n 4

.3: Brake

Re

si

sto

r Se

le

ctio

n

Fl

ow

Cha

rt

*) 40% (same as **)
**) See 10% tables in chapter Brake Resistor Overview.
***) See the chapter Calculation of the Brake Resistor.
****) Please provide the following info:

Nominal power 100%

Max. power during brake cycle

Braking time / Duty cycle

Supply voltage (max. DC)

Resistance (

Ω-value)

With or without thermswitch

IP enclosure rating

AF-650 GP Brake Resistor Design Guide

10

4

Advertising