12v picotlynx, 6a: non-isolated dc-dc power modules, Data sheet – GE Industrial Solutions 12V PicoTLynx 6A User Manual

Page 2: Absolute maximum ratings, Electrical specifications

Advertising
background image

GE

Data Sheet

12V PicoTLynx

TM

6A: Non-Isolated DC-DC Power Modules

4.5Vdc –14Vdc input; 0.59Vdc to 5.5Vdc output; 6A Output Current

May 2, 2013

©2013 General Electric Company. All rights reserved.

Page 2

Absolute Maximum Ratings

Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings
only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations
sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability.

Parameter

Device

Symbol

Min

Max

Unit

Input Voltage

All

V

IN

-0.3 15

Vdc

Continuous

Sequencing Voltage

APTS

V

SEQ

-0.3 V

iN

Vdc

Operating Ambient Temperature

All

T

A

-40 85

°C

(see Thermal Considerations section)

-D version

T

A

-40 105

°C

Storage Temperature

All

T

stg

-55 125

°C

Electrical Specifications

Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.

Parameter

Device

Symbol

Min

Typ

Max

Unit

Operating Input Voltage

All

V

IN

4.5 ⎯

14.0 Vdc

Maximum Input Current

All

I

IN,max

6.5 Adc

(V

IN

=4.5V to 14V, I

O

=I

O, max

)

Input No Load Current
(V

IN

= 12.0Vdc, I

O

= 0, module enabled)

V

O,set

= 0.6 Vdc

I

IN,No load

16

mA

V

O,set

= 3.3Vdc

I

IN,No load

55

mA

Input Stand-by Current

(V

IN

= 12.0Vdc, module disabled)

All I

IN,stand-by

1.2

mA

Inrush Transient

All

I

2

t

1

A

2

s

Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 1μH source impedance; V

IN

=0 to 14V

,

I

O

= I

Omax

; See Test Configurations)

All

86

mAp-p

Input Ripple Rejection (120Hz)

All

50

dB

CAUTION: This power module is not internally fused. An input line fuse must always be used.

This power module can be used in a wide variety of applications, ranging from simple standalone operation to an integrated part of

sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included; however, to achieve maximum
safety and system protection, always use an input line fuse. The safety agencies require a fast-acting fuse with a maximum rating

of 6A (see Safety Considerations section). Based on the information provided in this data sheet on inrush energy and maximum dc
input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data sheet for further
information.

Advertising