GE Industrial Solutions FLT012A0-SZ User Manual

Features, Applications, Options

Advertising
background image

Data Sheet
February 9, 2012

FLT012A0Z/FLT012A0-SZ Input Filter Modules

75Vdc Input Voltage Maximum; 12A Output Current Maximum

*

UL is a registered trademark of Underwriters Laboratories, Inc.

CSA is a registered trademark of Canadian Standards Association.

VDE is a trademark of Verband Deutscher Elektrotechniker e.V.

** ISO is a registered trademark of the International Organization of Standards

§

This product is intended for integration into end-user equipment . All of the required procedures of end-use equipment should be followed.

Document No:DS11-026 ver 1.2

PDF name: FLT012A0Z_FLT012A0-SZ_ds.pdf


Features

Compliant to RoHS EU Directive 2002/95/EC (Z
versions)

Compatible in a Pb-free or SnPb reflow environment
(Z versions)

Surface Mount and Through hole versions

Common-mode and Differential-mode filtering

Small size and low profile

48.3 mm x 25.4 mm x 11.7 mm
(1.9 in x 1.0 in x 0.46 in)

Same footprint as FLTR100V10 module

Cost efficient open frame design

Wide operating temperature range (-40°C to

+85°C)

Meets the voltage isolation requirements for
ETSI 300-132-2

UL* 60950-1, 2

nd

Ed. Recognized, CSA

C22.2 No.

60950-1-07 Certified, and VDE

(EN60950-1, 2

nd

Ed.)

Licensed

CE mark meets 2006/95/EC directives

§

ISO** 9001 and ISO 14001 certified manufacturing
facilities

Applications

Distributed power architectures

Wireless Networks

Enterprise Networks

Access and Optical Network Equipment

Options

Surface Mount Interconnect (-S)

Description

The Filter module shall be designed to operate over an input voltage range up to 75Vdc at output current
of 12A in an ambient temperature of -40ºC to 85ºC. The filter module shall be optimized for use with
dc/dc converter modules, to significantly reduce the conducted differential and common-mode noise
returned to the power source. The filter module shall enable designers to meet the requirements of EMI
standards CISPR 22 (EN55022) and FCC Class B by inserting in-line between the power source and the
dc/dc converter module. These modules shall be designed and manufactured to be either surface
mounted

(-S version)

or through hole mounted on PCBs.

Advertising