Terminal board points, 1 digital inputs terminal board points, 2 relay outputs terminal board points – GE Industrial Solutions D8R4 expanded I_O for AV-300i Drives User Manual

Page 7

Advertising
background image

7

—————— I/O Expansion card ——————

D8R4

3. TERMINAL BOARD POINTS

3.1 DIGITAL INPUTS TERMINAL BOARD POINTS

Connectors XDI0 and XDI1 have different ground connection.

Connector

Terminal

31

32

33

34

35

36

37

38

39

40

Function DI0 DI1 DI2 DI3 GND DI4 DI5 DI6 DI7 GND

exp10

DIGITAL INPUTS

XDI1

XDI0

3.2 RELAY OUTPUTS TERMINAL BOARD POINTS

Relay outputs need a +24V (60mA) supply voltage.

The Drive TB can be used to supply 24VDC power. AV-300i 24VDC supply
maximum output = 120 mA total including Encoder, LAN, Expansion card and
DGF (or 350 mA without DGF).

Connector

Relay

Terminal

114

111

112

214

211

212

Function N.Open

COM N.Closed N.Open

COM N.Closed

Connector

Relay

Terminal

314

311

312

414

411

412

Function N.Open

COM N.Closed N.Open

COM N.Closed

exp20

R2

R3

RELAY OUTPUTS

RELAY OUTPUTS

XCQ1

XCQ0

R0

R1

Connector

Terminal

100

101

Function

0V power supply

+24V power supply

exp30

RELAY OUTPUTS POWER SUPPLY

XSC