Naos Raptor 40A Non Isolated Power Module:

5 – 13.8Vdc input; 0.6Vdc to 5.0Vdc Output; 40A output current

LINEAGE

POWER

2


Absolute Maximum Ratings

Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are
absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in
excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for
extended periods can adversely affect the device reliability.

Parameter

Device

Symbol

Min

Max

Unit

Input Voltage

Continuous All

V

IN

-0.3 15 Vdc

Operating Ambient Temperature

All

T

A

0 70 °C

(see

Thermal

Considerations

section)

Storage Temperature

All

T

stg

-55 125 °C

Electrical Specifications

Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.

Parameter

Device

Symbol

Min

Typ

Max

Unit

Operating Input Voltage

All

V

IN

5 13.8

Vdc

Maximum Input Current

All

I

IN,max

30

Adc

(V

IN

= V

IN, min

to V

IN, max

, I

O

=I

O, max

V

O,set

= 3.3Vdc)

Input No Load Current

V

O,set

= 0.6 Vdc

I

IN,No load

165

mA

(V

IN

= 12Vdc, I

O

= 0, module ON)

V

O,set

= 5.0Vdc

I

IN,No load

360

mA

Input Stand-by Current

All

I

IN,stand-by

23

mA

(V

IN

= 12Vdc, module disabled)

Inrush Transient

All

I

2

t

1

A

2

s

Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 1μH source impedance; V

IN, min

to

V

IN, max,

I

O

= I

Omax

; See Test configuration section)

All

130

mAp-p

Input Ripple Rejection (120Hz)

All

50

dB

CAUTION: This power module is not internally fused. An input line fuse must always be used.

This power module can be used in a wide variety of applications, ranging from simple standalone operation to being
part of a complex power architecture. To preserve maximum flexibility, internal fusing is not included, however, to
achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a fast-
acting fuse with a maximum rating of 30A (see Safety Considerations section). Based on the information provided in
this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be
used. Refer to the fuse manufacturer’s data sheet for further information.