Electrical specifications (continued), General specifications – GE Industrial Solutions NQR010A0X4 User Manual
Page 4
Data Sheet
March 7, 2012
NQR010A0X4: Non-Isolated DC-DC Power Modules
4.5 – 14Vdc input; 0.59Vdc to 6Vdc Output; 10A output current
LINEAGE
POWER
4
Electrical Specifications
(continued)
Parameter
Device
Symbol
Min
Typ
Max
Unit
Dynamic Load Response
(dIo/dt=10A/
μs; V
IN
= V
IN, nom
; V
out
= 1.8V, T
A
=25°C)
Load Change from Io= 0% to 50% of Io,max;
Co = 10
μF
Peak Deviation
All
V
pk
280 mV
Settling Time (Vo<10% peak deviation)
All t
s
40
μs
Load Change from Io= 50% to 0%of Io,max:
Co = 10
μF
Peak Deviation
All
V
pk
325 mV
Settling Time (Vo<10% peak deviation)
All t
s
40
μs
General Specifications
Parameter
Min
Typ
Max
Unit
Calculated MTBF (V
IN
=12V, V
O
=5Vdc, I
O
=0.8I
O, max
, T
A
=40°C) Per
Telcordia Method
6,925,356 Hours
Weight
⎯
2.5 (0.088)
⎯
g (oz.)