Electrical specifications (continued), General specifications – GE Industrial Solutions NQR010A0X4 User Manual

Page 4

Advertising
background image

Data Sheet
March 7, 2012

NQR010A0X4: Non-Isolated DC-DC Power Modules

4.5 – 14Vdc input; 0.59Vdc to 6Vdc Output; 10A output current

LINEAGE

POWER

4

Electrical Specifications

(continued)

Parameter

Device

Symbol

Min

Typ

Max

Unit

Dynamic Load Response

(dIo/dt=10A/

μs; V

IN

= V

IN, nom

; V

out

= 1.8V, T

A

=25°C)

Load Change from Io= 0% to 50% of Io,max;
Co = 10

μF

Peak Deviation

All

V

pk

280 mV

Settling Time (Vo<10% peak deviation)

All t

s

40

μs

Load Change from Io= 50% to 0%of Io,max:
Co = 10

μF

Peak Deviation

All

V

pk

325 mV

Settling Time (Vo<10% peak deviation)

All t

s

40

μs

General Specifications

Parameter

Min

Typ

Max

Unit

Calculated MTBF (V

IN

=12V, V

O

=5Vdc, I

O

=0.8I

O, max

, T

A

=40°C) Per

Telcordia Method

6,925,356 Hours

Weight

2.5 (0.088)

g (oz.)















Advertising