6a analog picodlynx, Non-isolated dc-dc power modules, Preliminary data sheet – GE Industrial Solutions 6A Analog PicoDLynx User Manual

Page 15: Module

Advertising
background image

GE

Preliminary Data Sheet

6A Analog PicoDLynx

TM

: Non-Isolated DC-DC Power Modules

3Vdc –14.4Vdc input; 0.6Vdc to 5.5Vdc output; 6A Output Current

December 7, 2012

©2012 General Electric Company. All rights reserved.

Page 15

Tunable Loop

TM

The 6A PicoDLynx

TM

modules have a feature that optimizes

transient response of the module called Tunable Loop

TM

.

External capacitors are usually added to the output of the
module for two reasons: to reduce output ripple and noise (see
Figure 38) and to reduce output voltage deviations from the

steady-state value in the presence of dynamic load current
changes. Adding external capacitance however affects the
voltage control loop of the module, typically causing the loop to

slow down with sluggish response. Larger values of external
capacitance could also cause the module to become unstable.

The Tunable Loop

TM

allows the user to externally adjust the

voltage control loop to match the filter network connected to
the output of the module. The Tunable Loop

TM

is implemented

by connecting a series R-C between the SENSE and TRIM pins of
the module, as shown in Fig. 45. This R-C allows the user to
externally adjust the voltage loop feedback compensation of

the module.

Figure. 45. Circuit diagram showing connection of R

TUME

and

C

TUNE

to tune the control loop of the module.

Recommended values of R

TUNE

and C

TUNE

for different output

capacitor combinations are given in Tables 2 and 3. Table 2
shows the recommended values of R

TUNE

and C

TUNE

for different

values of ceramic output capacitors up to 1000uF that might

be needed for an application to meet output ripple and noise
requirements. Selecting R

TUNE

and C

TUNE

according to Table 2

will ensure stable operation of the module.
In applications with tight output voltage limits in the presence
of dynamic current loading, additional output capacitance will

be required. Table 3 lists recommended values of R

TUNE

and

C

TUNE

in order to meet 2% output voltage deviation limits for

some common output voltages in the presence of a 3A to 6A

step change (50% of full load), with an input voltage of 12V.

Please contact your GE technical representative to obtain more
details of this feature as well as for guidelines on how to select
the right value of external R-C to tune the module for best
transient performance and stable operation for other output
capacitance values or input voltages other than 12V.

Table 2. General recommended values of of R

TUNE

and

C

TUNE

for Vin=12V and various external ceramic

capacitor combinations.

Co

1x47

μF 2x47μF 4x47μF 6x47μF 10x47μF

R

TUNE

330 270 220 180 180

C

TUNE

680pF 1800pF 3300pF 4700pF 5600pF




Table 3. Recommended values of R

TUNE

and C

TUNE

to

obtain transient deviation of 2% of Vout for a 3A step

load with Vin=12V.

Vo

5V

3.3V

2.5V

1.8V

1.2V

0.6V

Co 2x47μF 3x47μF

3x47

μF

1x330

μF

Polymer

2x330

μF

Polymer

4x330

μF

Polymer

R

TUNE

270 180 180 180 180 180

C

TUNE

2200pF 3300pF 3300pF 4700pF 12nF

33nF

ΔV 76mV 48mV 47mV 33mV 18mV 10mV


Note: The capacitors used in the Tunable Loop tables

are 47 μF/3 mΩ ESR ceramic and 330 μF/12 mΩ ESR
polymer capacitors.



MODULE

VOUT

SENSE

TRIM

GND

RTUNE

CTUNE

RTrim

C O

Advertising