Data sheet, General specifications, Feature specifications – GE Industrial Solutions KHHD010A0A Hammerhead Series User Manual

Page 4

Advertising
background image

GE

Data Sheet

KHHD010A0A Hammerhead™ Series; DC-DC Converter Power Modules

18-75Vdc Input; 5.0Vdc, 8A/10A Output

February 24, 2014

©2012 General Electric Company. All rights reserved.

Page 4

General Specifications

Feature Specifications

Unless otherwise indicated, specifications apply at V

IN

= 48V

dc

, resistive load, and T

A

= 25°C conditions. See Feature Descriptions for

additional information.

Parameter

Device

Symbol

Min

Typ

Max

Unit

Remote On/Off Signal Interface

(V

IN

=V

IN, min

to V

IN, max

; open collector or equivalent,

Signal referenced to V

IN-

terminal)

Negative Logic: device code suffix “1”

Logic Low = module On, Logic High = module Off

Positive Logic: No device code suffix required

Logic Low = module Off, Logic High = module On

Logic Low - Remote On/Off Current (V

on/off

= -0.7V

dc

)

All

I

on/off

0.15

mA

Logic Low - On/Off Voltage

All

V

on/off

-0.7

0.8

V

dc

Logic High Voltage (I

on/off

= 0A

dc

)

All

V

on/off

2.4

7

V

dc

Logic High maximum allowable leakage current

All

I

on/off

25

μA

Turn-On Delay and Rise Times

(I

O

=80% of I

O, max

)

Case 1: Input power is applied for at least 1second, and then the
On/Off input is set from OFF to ON (T

delay

= on/off pin transition until

V

O

= 10% of V

O, set

)

All

T

delay

Case1

25

50

ms

Case 2: On/Off input is set to Module ON, and then input power is

applied
(T

delay

= V

IN

reaches V

IN, min

until V

O

= 10% of V

O,set

)

All

T

delay

Case2

35

50

ms

Output voltage Rise time (time for V

o

to rise from 10%

of V

o,set

to 90% of V

o, set

)

All

T

rise

5

10

ms

Output Voltage Overshoot

3

% V

O, set

(I

O

=80% of I

O, max

, V

IN

= 24 to 48V

dc

)

Output Overvoltage Protection

All

V

O, limit

6.0

7.0

V

dc

Input Undervoltage Lockout

Turn-on Threshold

All

V

uv/on

17

18

V

dc

Turn-off Threshold

All

V

uv/off

14

15

V

dc

Hysterisis

All

V

hyst

2.0

V

dc

Note: 1.The module requires a minimum of 680 μF external output capacitor to avoid exceeding the OVP maximum limits during startup into open
loop fault conditions.

Parameter

Min

Typ

Max

Unit

Calculated Reliability based upon Telcordia SR-332 Issue 2: Method

I

Case 3

(I

O

=80%I

O, max

, T

A

=40°C, airflow = 200 lfm, 90% confidence)

FIT

272.0

10

9

/Hours

MTBF

3,677,136

Hours

Weight

13 (0.46)

g (oz.)

Advertising