Data Sheet

3A Digital PicoDLynx

TM

: Non-Isolated DC-DC Power Modules

3Vdc –14.4Vdc input; 0.45Vdc to 5.5Vdc output; 3A Output Current

April 29, 2013

©2013 General Electric Company. All rights reserved.

Page 31


Table

6

(continued)

Hex

Code

Command

Brief Description

Non-Volatile

Memory Storage

A0 MFR_VIN_MIN

Returns the minimum input voltage the module is specified to operate at (read only)

Format

Linear, two’s complement binary

Bit Position

7 6 5 4 3 2 1 0

Access

r r r

r

r

r

r r

Function

Exponent Mantissa

Default Value

1 1 1 1 0 0 0 0

Bit Position

7 6 5 4 3 2 1 0

Access

r r r

r

r

r

r r

Function

Mantissa

Default Value

0 0 0 0 1 1 0 0

YES

A4 MFR_VOUT_MIN

Returns the minimum output voltage possible from the module (read only)

Format

Linear, two’s complement binary

Bit Position

7 6 5 4 3 2 1 0

Access

r r r

r

r

r

r r

Function

Mantissa

Default Value

0 0 0 0 0 0 1 0

Bit Position

7 6 5 4 3 2 1 0

Access

r r r

r

r

r

r r

Function

Mantissa

Default Value

0 1 1 0 0 1 1 0

YES

D0 MFR_SPECIFIC_00

Returns module name information (read only)

Format

Unsigned Binary

Bit Position

7 6 5 4 3 2 1 0

Access

r r r

r

r

r

r r

Function

Reserved

Default Value

1 1 1 0 1 0 0 0

Bit Position

7 6 5 4 3 2 1 0

Access

r r r

r

r

r

r r

Function

Module Name

Reserved

Default Value

0 0 1 0 0 0 1 0

YES

D4 VOUT_CAL_OFFSET

Applies an offset to the READ_VOUT command results to calibrate out offset errors in
module measurements of the output voltage (between -125mV and +124mV)

Format

Linear, two’s complement binary

Bit Position

7 6 5 4 3 2 1 0

Access

r/w r r

r

r

r

r r

Function

Mantissa

Default Value

V 0 0 0 0 0 0 0

Bit Position

7 6 5 4 3 2 1 0

Access

r/w r/w r/w

r/w

r/w

r/w

r/w r/w

Function

Mantissa

Default Value

V V V V V V V V

YES

D5 VOUT_CAL_GAIN

Applies a gain correction to the READ_VOUT command results to calibrate out gain
errors in module measurements of the output voltage (between -0.125 and 0.121)

Format

Linear, two’s complement binary

Bit Position

7 6 5 4 3 2 1 0

Access

r r r

r

r

r

r r/w

Function

Exponent Mantissa

Default Value

1 1 0 0 0 0 0 V

Bit Position

7 6 5 4 3 2 1 0

Access

r/w r/w r/w

r/w

r/w

r/w

r/w r/w

Function

Mantissa

Default Value

V V V V V V V V

YES