Thermal Considerations

Power modules operate in a variety of thermal environments;
however, sufficient cooling should always be provided to help
ensure reliable operation.

Considerations include ambient temperature, airflow, module
power dissipation, and the need for increased reliability. A
reduction in the operating temperature of the module will result
in an increase in reliability. The thermal data presented here is
based on physical measurements taken in a wind tunnel. The

test set-up is shown in Figure 46. The preferred airflow
direction for the module is in Figure 47.

Air

flow

x

Power Module

Wind Tunnel

PWBs

12.7_

(0.50)

76.2_

(3.0)

Probe Location
for measuring
airflow and
ambient
temperature

25.4_

(1.0)

Figure 46. Thermal Test Setup.

The thermal reference points, T

ref

used in the specifications are

also shown in Figure 47. For reliable operation the
temperatures at these points should not exceed 120

o

C. The

output power of the module should not exceed the rated power
of the module (Vo,set x Io,max).

Please refer to the Application Note “Thermal Characterization
Process For Open-Frame Board-Mounted Power Modules” for a
detailed discussion of thermal aspects including maximum

device temperatures.


Figure 47. Preferred airflow direction and location of
hot-spot of the module (Tref).