Isolation specifications general specifications – GE Industrial Solutions HW006-010-012 Series User Manual
Page 4
Lineage Power
4
Data Sheet
June 26, 2009
36-75 Vdc Input; 1.2 Vdc to 5 Vdc Output; 6.6A to 12A
HW006/010/012 Series Power Modules; dc-dc Converters
Electrical Specifications
(continued)
Isolation Specifications
General Specifications
Parameter
Device
Symbol
Min
Typ
Max
Unit
Dynamic Load Response
(di/dt = 0.1 A/ µs, VI = VI, nom, TA = 25 °C)
Load change from IO = 50% to 75% of IO, max,
Peak Deviation
Settling Time (VO < 10% of peak deviation)
Load Change from IO = 50% to 25% of IO, max,
Peak Deviation
Setting Time (VO < 10% peak deviation)
All
All
All
All
—
—
—
—
—
—
—
—
200
0.2
200
0.2
—
—
—
—
mV
msec
mV
msec
Parameter
Symbol
Min
Typ
Max
Unit
Isolation Capacitance
Ciso
—
1000
—
PF
Isolation Resistance
Riso
10
—
—
M
Ω
Isolation Voltage
Viso
—
—
1500
Vdc
Parameter
Min
Typ
Max
Unit
Calculated MTBF (IO = 80% of IO, max TA = 25 °C)
RIN (Reliability Infomation Notebook) Method
4,537,000
Hours
Weight
—
13 (0.46)
—
g (oz.)