Absolute maximum ratings, Electrical specifications – GE Industrial Solutions QW030xx DUAL Series User Manual

Page 2

Advertising
background image

2

Lineage Power

Data Sheet

October 2008

18 Vdc to 36 Vdc or 36 Vdc to 75 Vdc Inputs

QW030xx DUAL Series Power Modules: dc-dc Converters;

Absolute Maximum Ratings

Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are
absolute stress ratings only. Functional operation of the device is not implied at these or any other conditions in
excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for
extended periods can adversely affect device reliability.

* Maximum case temperature varies based on power dissipation. See power derating curves for details.

Electrical Specifications

Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.

Table 1. Input Specifications

Fusing Considerations

CAUTION: This power module is not internally fused. An input line fuse must always be used.

This encapsulated power module can be used in a wide variety of applications, ranging from simple stand-alone
operation to an integrated part of a sophisticated power architecture. To preserve maximum flexibility, internal
fusing is not included; however, to achieve maximum safety and system protection, always use an input line fuse.
The safety agencies require a normal-blow fuse with a maximum rating of 5 A (see Safety Considerations section).
Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same
type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data for further information.

Parameter

Device

Symbol

Min

Max

Unit

Input Voltage:

Continuous

Transient (100 ms)

QW030xx
QW030xx

I

V

I

V

I, trans



80

100

Vdc

V

Operating Case Temperature

(See Thermal Considerations section.)

QW030xx

Tc

–40

105*

°C

Storage Temperature

QW030xx

T

stg

–55

125

°C

I/O Isolation Voltage

(Note case is tied to input)

QW030xx

1500

Vdc

Parameter

Device

Symbol

Min

Typ

Max

Unit

Operating Input Voltage:

QW030xx

QW030xx

V

I

36

48

75

Vdc

Maximum Input Current

(V

I

= 0 V to 75 V; I

O

= I

O, max

):

QW030xx

QW030xx

I

I, max

2.2

A

Inrush Transient

QW030xx

i

2

t

0.2

A

2

s

Input Reflected-ripple Current, Peak-to-peak

(5 Hz to 20 MHz, 12 µH source impedance;
see Test Configurations section.)

QW030xx

I 15

mAp-p

Input Ripple Rejection (120 Hz)

QW030xx

50

dB

Advertising