Absolute maximum ratings, Electrical specifications – GE Industrial Solutions JNC350R Series User Manual

Page 2

Advertising
background image

Data Sheet

August 9, 2010

JNC350R Power Modules; DC-DC Converters

18 – 36 Vdc Input; 28Vdc Output; 350W Output

LINEAGE

POWER

2

Absolute Maximum Ratings

Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are
absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in
excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for
extended periods can adversely affect the device reliability.

Parameter

Device

Symbol

Min

Max

Unit

Input Voltage

Continuous

All V

IN

-0.3 40 V

dc

Transient, operational (≤100 ms)

All

V

IN,trans

-0.3 50 V

dc

Operating Ambient Temperature
Please contact your Lineage Power Sales representative
for information on thermal derating when using forced
airflow.

All Ta

-40 85 °C

Operating Case Temperature
(See Thermal Considerations section, Figure 20)

All Tc -40 100 °C

Storage Temperature

All

T

stg

-55 125 °C

I/O Isolation Voltage: Input to Case, Input to Output

All

1500 V

dc

Output to Case

All

500 V

dc

Electrical Specifications

Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.

Parameter

Device

Symbol

Min

Typ

Max

Unit

Operating Input Voltage
(see Figure 12 for V

IN, min

when using trim-up feature)

All V

IN

18 24

36 V

dc

Maximum Input Current

All I

IN,max

25 A

dc

(V

IN

=18V to 36V, I

O

=I

O, max

)

Inrush Transient

All

I

2

t

2

A

2

s

Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 12μH source impedance; V

IN

=0V to 36V,

I

O

= I

Omax

; see Figure 7)

All

25 mA

p-p

CAUTION: This power module is not internally fused. An input line fuse must always be used.

This power module can be used in a wide variety of applications, ranging from simple standalone operation to being
an integrated part of complex power architecture. To preserve maximum flexibility, internal fusing is not included.
Always use an input line fuse, to achieve maximum safety and system protection. The safety agencies require a fast-
acting fuse with a maximum rating of 30 A (see Safety Considerations section). Based on the information provided in
this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be
used. Refer to the fuse manufacturer’s data sheet for further information.