Hardware description, 1 mounting – GE Industrial Solutions ISBus interface board for AV-300i Drives User Manual

Page 4

Advertising
background image

—————— Expansion board ——————

4

GEI-100424

1. HARDWARE DESCRIPTION

1.1 MOUNTING

The ISBus card is supplied with standoffs, screws, washers and a ISBus
connectors.

1.

Switch the drive off.

2.

Fasten the ISBus card to the drive regulation board by means of screws
(B) and standoffs (A). The SBI-Drive connector (C) must be connected
between X0 (on Regulation board) and X0 (on ISBus card).

3.

Switch on the drive.

4.

The LED H1 lights up.

N

OTE

:

ISBus functionality requires AV300i software version 2.00
or higher

N

OTE

:

Refer to GEH 6380 for ISBus cabling and hookup.

B

C

A

Tx

Rx Tx

Advertising