Data Sheet

August 23, 2010

36 Vdc - 75 Vdc Input, 1.2 to 3.3 Vdc Output; 25A

QRW025 Series Power Modules; dc-dc Converters

remain withing SELV limits even with internally-generated

non-SELV voltages. Single component failure and fault

tests were performed in the power converters.

n

One pole of the input and one pole of the output are to be

grounded, or both circuits are to be kept floating, to main-

tain the output voltage to ground voltage within ELV or

SELV limits.

For all input sources, other than DC MAINS, where the input

voltage is between 60 and 75 Vdc (Classified as TNV-2 in

Europe), the following must be adhered to, if the converter’s

output is to be evaluated for SELV:

n

The input source is to be provided with reinforced insula-

tion from any hazardous voltage, including the AC mains.

n

One VI pin and one VO pin are to be reliably earthed, or

both the input and output pins are to be kept floating.

n

Another SELV reliability test is conducted on the whole

system, as required by the safety agencies, on the combi-

nation of supply source and the subject module to verify

that under a single fault, hazardous voltages do not appear

at the module’s output.

The power module has ELV (extra-low voltage) outputs when

all inputs are ELV.
All flammable materials used in the manufacturing of these
modules are rated 94V-0, and UL60950A.2 for reduced thick-
nesses. The input to these units is to be provided with a max-
imum 10A normal-blow fuse in the ungrounded lead.