12a analog slimlynx, Open frame: non-isolated dc-dc power modules, Data sheet – GE Industrial Solutions 12A Analog SlimLynx Open Frame User Manual

Page 15

Advertising
background image

GE

Data Sheet

12A Analog SlimLynx

TM

Open Frame: Non-Isolated DC-DC Power Modules

3Vdc –14.4Vdc input; 0.6Vdc to 5.5Vdc output; 12A Output Current

February 19, 2014

©2014 General Electric Corporation. All rights reserved.

Page 15


output reaches the set-point voltage. The final value of the
sequencing voltage must be set higher than the set-point

voltage of the module. The output voltage follows the
sequencing voltage on a one-to-one basis. By connecting
multiple modules together, multiple modules can track their
output voltages to the voltage applied on the SEQ pin.

The module’s output can track the SEQ pin signal with slopes
of up to 0.5V/msec during power-up or power-down.
To initiate simultaneous shutdown of the modules, the SEQ
pin voltage is lowered in a controlled manner. The output
voltage of the modules tracks the voltages below their set-
point voltages on a one-to-one basis. A valid input voltage
must be maintained until the tracking and output voltages
reach ground potential.

Overcurrent Protection

To provide protection in a fault (output overload) condition,
the unit is equipped with internal current-limiting circuitry
and can endure current limiting continuously. At the point of

current-limit inception, the unit enters hiccup mode. The unit
operates normally once the output current is brought back
into its specified range.

Overtemperature Protection

To provide protection in a fault condition, the unit is

equipped with a thermal shutdown circuit. The unit will shut
down if the overtemperature threshold of 150

o

C(typ) is

exceeded at the thermal reference point T

ref

.Once the unit

goes into thermal shutdown it will then wait to cool before
attempting to restart.

Input Undervoltage Lockout

At input voltages below the input undervoltage lockout limit,
the module operation is disabled. The module will begin to

operate at an input voltage above the undervoltage lockout
turn-on threshold.

Synchronization

The module switching frequency can be synchronized to a
signal with an external frequency within a specified range.
Synchronization can be done by using the external signal

applied to the SYNC pin of the module as shown in Fig. 45,
with the converter being synchronized by the rising edge of
the external signal. The Electrical Specifications table
specifies the requirements of the external SYNC signal. If the
SYNC pin is not used, the module should free run at the

default switching frequency. If synchronization is not being

used, connect the SYNC pin to GND.

MODULE

SYNC

GND

+


Figure 45. External source connections to synchronize

switching frequency of the module.

Dual Layout

Identical dimensions and pin layout of Analog and Digital

SlimLynx

TM

Open Frame modules permit migration from one

to the other without needing to change the layout. In both

cases the trim resistor is connected between trim and signal
ground. The output of the analog module cannot be
trimmed down to 0.45V

Power Good

The module provides a Power Good (PGOOD) signal that is
implemented with an open-drain output to indicate that the
output voltage is within the regulation limits of the power
module. The PGOOD signal will be de-asserted to a low state

if any condition such as overtemperature, overcurrent or
loss of regulation occurs that would result in the output
voltage going ±10% outside the setpoint value. The PGOOD

terminal can be connected through a pullup resistor
(suggested value 100K

Ω) to a source of 5VDC or lower.

Advertising