Comfort Stat CP1819 User Manual

Programmable thermostat, R e tur n, Owners manual

Advertising
background image

day/time 

program 

PROGRAMMABLE THERMOSTAT 

Owners Manual 

Model : CP1819 

L 

Congratulations! 

Your  new  thermostat  will  provide  years  of  reliable  service.  By  saving  energy,  your 

thermostat will pay for itself during its first season of use. Thanks you for buying our 

product! 

Please  read  this  manual  for  complete  instructions  on  installing  and  operating  your 

thermostat. If you require further assistance, please feel free to contact us 

IMPORTANT INFORMATION 

1. This thermostat is designed to work on the following systems: 
Ÿ Gas – Standing Pilot 

Ÿ Oil – Fired Furnace 

Ÿ Gas – Electronic Ignition 

Ÿ Single Stage Heat Pumps – 

with no auxiliary heat 

Ÿ Gas – Fired Boilers 

Ÿ Electric Air Conditioning 

Ÿ Gas – Millivolt Systems 

Ÿ Electric Furnace 

Ÿ Oil – Fired Boilers 

This  thermostat  will  NOT  control  multistage  heat  pumps  or  110/220V  baseboard 

electric heating systems. 

2. Temperature Range 

This thermostat can be programmed between 45˚F and 95˚F (7˚C and 35˚C). However, 

it  will  display  room  temperatures  from  30˚F  to  99˚F  (0˚C  and  37˚C).  “HI”  will  be 

displayed if the temperature is higher than 99˚F (37˚C), and “LO” will be displayed if 

the temperature is lower than 30˚F (0˚C). 

This thermostat will automatically cutoff in Heat mode if the temperature rises above 

95˚F  (35˚C),  and  automatically  cutoff  in  Cool  mode  if  the  temperature  drops  below 

45˚F (7˚C). 

3. Compressor Protection 

This thermostat provides a 4 minutes delay after shutting off the cooling system before 

it  can  be  restarted.  This  feature  will  prevent  damage to  your  compressor  caused  by 

rapid  cycling.  It  does  not  prevent  a  rapid  compressor  restart  due  to  short  power 

outages. 

4. Battery Warning 

Two fresh AA alkaline batteries should provide well about one year of service. However, 

when the batteries become drained, the Low Battery Indicator will flash on the display. 

When this  message  occurs,  install  new  alkaline  batteries.  You  have  approximately 1 

minute to change the batteries and keep the thermostat’s clock and program settings. 

Once the batteries have become too low to ensure proper operation, your system will 

be turned off, and the display will be cleared except for flashing Low Battery Indicator 

on the LCD display. 

CAUTION:  When  only  the  Low  Battery  icon  flashes  on  the  display, 

the thermostat is shut down, and your system will no longer operate. 

In this condition, there is no temperature control of your dwelling. 

NOTE: The backlight will not function when the thermostat is in low battery condition. 

NOTE:  If you  plan to  be  away  from  the  premises  over  30  days,  we  recommend  that 
you replace the old batteries with new alkaline batteries prior to leaving.
 

5.Power supply 

The thermostat shall be powered by 24 VAC and with batteries as backup. 

FEATURES 

Structure of thermostat and explanation for the keypads 

h ea t 

of f 

coo l 

on 

au to 

da y/ time 

filter 

p ro gr am 

hol d 

syst em 

f an 

LCD Display:Shows 
Time,Day,Temperature, 
Program Number,and 
other feature information 
as required. 

Backlight key 

Battery Compartment: 
Front access allows 
easy insertion of two 
AA 1.5V batteries. 

Up and Down Key:Key for 
changing the Temperature 
setting. Also used for increasing 
and decreasing selections in the 
Time,Program,and Span 
functions. 

/r e tur n 

Fan Switch: Fan 
switch for Automatic 
or Continuous fan 
operation. 

System Switch: 
Selector switch for 
Heat,Cool,and Off. 

Day/Time Key: 
Used for entering 
the Clock setting 
mode.Use with the 
Up and Down keys 
to set the time and day. 

Filter Key:Resets 
filter change 
counter to zero. 

Program Key: Used 
for entering and modifying 
Programs. Use with the Up 
and Down keys to set 
times and temperatures. 
Press when in Clock setting 
mode to select between 12 
and 24 hour clock modes. 

Hold/Return Key:Used for 
setting a permanent(vacation) 
hold,and for returning to the 
normal display from Day & 
Time setting, Programming,or 
Span setting modes. 

Front Door: 
Battery cover 
Open with one 
finger from top. 

Front Door: Cover keys Open with one finger from left or right. 

OPERATION 

Setting Day and Time 

Ÿ  The  LCD  will  show  this  information  when 

batteries  are  first  installed.  The  temperature  will 

update after a few seconds. 

Ÿ  During  time  and  day  setting  mode,  the 

temperature and program displays will go blank. 

Ÿ Examples: Set the Thermostat to the current time of 2:16 pm on Saturday. 

Refer to the Steps below. 

STEP 1: 

Ÿ  Press  to  enter  time  and  day  setting  mode.  The 

current  hour  and  the  AM/PM  indicator  will  be 

flashing. 

Ÿ Press up or down to change the Hour up or down 

to the current hour. 

Note the AM/PM indicator, as the display will change at 12AM and 12PM. 

STEP 2: 

Ÿ  Press  again  to  change  from  hour  setting  to 

minute setting. The current minute will be flashing. 

Ÿ  Press  up  or  down  to  change  the  Minute  up  or 

down to the current minute. 

STEP 3: 

Ÿ Press again to change from minute setting to day 

setting. The current days will be flashing. 

Ÿ Press up or down to change the Day up or down 

to the current day. 

STEP 4: 

Ÿ Press again to change back to the normal display. 

NOTE:  You  may  press 

/return  at  any  time  during  Day  and  Time  setting  to 

return to the normal display. 

12Hr. / 24 Hr. Time Format 

Your thermostat is set from the factory in normal 12 (AM/PM) time format. To change to 

24  hour  (military)  time,  press                            during  time  and  day  setting  mode  to 

toggle  between the  12  hour  and  24  hour  formats. The  AM /  PM  indicator  will  not  be 

displayed in 24 hour mode. Both the current time and all programs will automatically 

change to the selected format. 

PROGRAMMING 

The following time and temperature settings are pre­programmed into the thermostat: 

Temperature in F˚ (C˚) 

Program Number 

Time 

Heat 

Cool 

6:00 am 

68˚F(20˚C) 

78˚F(26˚C) 

8:00 am 

60˚F(16˚C) 

85˚F(29˚C) 

4:00 pm 

68˚F(20˚C) 

78˚F(26˚C) 

10:00 pm 

60˚F(16˚C) 

82˚F(28˚C) 

Ÿ

All 7 days of the week have the same default programs. 

Personal Program Schedule 

Ÿ

You can revise the factory programs to match your own schedule. Use this Personal 

Program  Schedule  to  determine  which  times  and  temperature  settings  match  your 

comfort and energy saving requirements. Use a pencil so you can revise your records 

each time you change your program settings. 

Heating 

Day 

Program 1 

Program 2 

Program 3 

Program 4 

Monday  – 

Friday 

Time 

Temp 

Time 

Temp 

Time 

Temp 

Time 

Temp 

Saturday  – 

Sunday 

Time 

Temp 

Time 

Temp 

Time 

Temp 

Time 

Temp 

Cooling 

Day 

Program 1 

Program 2 

Program 3 

Program 4 

Monday  – 

Friday 

Time 

Temp 

Time 

Temp 

Time 

Temp 

Time 

Temp 

Saturday  – 

Sunday 

Time 

Temp 

Time 

Temp 

Time 

Temp 

Time 

Temp 

Revising Programs 

Ÿ Familiarize yourself with manually changing programs, so that you can easily modify 

the  programs  as  your comfort  needs change. Follow  the  steps  below  to  change the 

program times and temperature. 

NOTE: 

1) The program time can be set in 10­minute increments. 

2) The program temperature can be set in increments of 1˚F (1˚C). 

3)  After 15 seconds without a key press, the thermostat will return to normal display 

mode. 

4) When setting the program time, note the AM / PM indicator. 

STEP 1: 

ŸSlide the System Switch to the HEAT or COOL position to program the 

corresponding system. 

NOTE: if the System Switch is in the off position, 

the last position used will be programmed. 

STEP 2: 

Ÿ Press to enter program mode. HEAT or COOL will be displayed on the 

LCD. 

STEP 3: 

Ÿ The Program hour and AM or PM indicator are 

flashing. Press to change the hour. 

STEP 4: 

Ÿ Press again to change to the minute position. The 

current minute will be flashing. 

Ÿ Press to change the minute. 

STEP 5: 

Ÿ  Press  again  to  change  to  the  program  temperature.  The 

current program will be flashing. 

Ÿ Press to change the temperature. 

STEP 6: 

Ÿ Press again to move to the next program number. 

Ÿ Repeat Step 3 through 5 to change the remaining Weekday and 

Weekend programs. (There are a total of 8 programs) 

Ÿ After cycling through all 8 programs, press again to return the display to 

normal. 

Ÿ Press at any time to exit the program Mode. 

Reviewing Programs 

To  review  your  program  settings,  press 

repeatedly to cycle through 

the programs. You can also make changes at any time. 

System selector Switch 

The  System  Selector  switch  on  the  front  of  the  thermostat 

determines  the  operating  mode  of  the thermostat.  You  may  select 

COOL, OFF, HEAT. 

NOTE:  Anytime  you  install  or  remove  the  thermostat  from  the  wall  plate,  slide  the 

System  Selector  to  the  OFF  position  to  prevent  the  possibility  of  a  rapid  system 

On­Off. 

Fan switch 

The  Fan  switch should  normally  be  located  in  the  AUTO  position. 

The  Fan  will  be  turned  on  along  with  normal  operation  of  your 

system. In a normal gas or oil furnace, the Fan will be turned on by 

your furnace after its warm­up delay. For electric heat, air conditioning, and heat pump 

operation, the Fan will turn on with the system. To run the Fan on continuously, slide 

the Fan switch to the ON position. 

Temporary Manual Override 

To  temporarily  change  the  current  set  temperature  without  affecting  your 

program

Ÿ Press to change to your desired Set Temperature. 

Hold the key for 2 seconds to fast­advance the Set 

Temperature. 

Ÿ Press to return to normal mode, or wait 5 seconds 

for it to return automatically. 

Ÿ The current program number will flash to signify the Temporary Override. 

Ÿ  At the next program change time, the  Temporary Override is 

cancelled,and  the  next  program  temperature    becomes  the 

setpoint    temperature. 

Ÿ  Press  to  confirm  the  Temporary 

Override, 

Permanent Override or a Designated Day Override 

To  hold  your  Manual  Override  for  vacation  or  Until  a 

Designated Day. 

Ÿ  Press  to  make  the  current  program 

temperature  the  HOLD  temperature. 

HOLD will be displayed on the LCD, and the Program number 

will disappear. 

Ÿ Follow the Temporary Manual Override instructions above to change the 

Permanent Manual Override temperature. 

Ÿ You can confirm the held set temperature by pressing for less than 1 

second. 

Ÿ Press again. Hold day will be displayed 

on the lcd and the clock will disappear. 

ŸPress  Day  key  to  add  override  days.  Press 

Program key to reduce override days. 

Ÿ  Follow  the  Temporary  a  Designated  Day 

Override instructions above to change the Permanent Manual Override 

temperature. 

To end Override: 

ŸUnder  Permanent  Override  Press  hold/return  key  twice.  Under  a  Designated  Day 

Override press the hold/return once. The thermostat will return 

to the current program, and the HOLD display will be canceled. 

Filter Change Indicator 

Your thermostat also keeps a record of the number of hours your filter has been in use. 

To Maximize your system’s performance and energy efficiency, change or clean your 

filter regularly. 

Ÿ  When  the  total  system  runtime  for  heat  and  cool  reaches 

400  hours,  “FILT”  will  alternate  with  the  current 

time  on  the  LCD  display  to  remind  you  need 

clean or change your system’s filter. ”Filt” will continue to flash 

until the counter is set back to zero. 

ŸPress  to  review  total  filter  usage.  The  display  will  blink  ”FILT”, then  show  the  Filter 

Monitor counter. After 15 seconds, the display will return to normal mode 

In  this  example,  the  counter  is  at  410  Hours, 

26Minutes. 

ŸTo  reset  the  Filter  Monitor  counter,  depress  Filter  key  for  3 

seconds. the display will blink,and the counter will be reset to 

zero. 

SPAN Setting 

Your  thermostat  is  set  at  the  factory  to  cycle  at  2˚F  (1˚C)  above  and  below  the  set 

temperature. (Span = 2) This setting has been designed to provide a comfortable room 

temperature  under  most  all  conditions.  However,  if  you  find  your  system 

cycling too fast or too slow, then the Span can be adjusted to modify the 

cycle time. 

Ÿ  Press  and  hold  BOTH  (up  and  down  keys)  for 

three  seconds.  The  display  will  flash,  and  SPAN 

will be displayed on the LCD. 

Ÿ  Press  to  raise  the  Span  to  3.  This  setting 

INCREASES to cycle time by allowing your system 

to run LONGER. 

Ÿ Press to lower the Span to 1. This setting DECREASES the cycle time 

by causing your system to run SHORTER. 

The  Span  settings  remain  the  same  for  both  HEAT  and  COOL.  The  Span  can  be 

changed at any time, and is independent of program times or temperatures. 

Backlighting 

Your  thermostat has  an  electroluminescent  lamp  that  backlights  the  display  for  easy 

viewing in the dark. 

When any key is pressed , the display is illuminated. 

The  display  will  remain  illuminated  for  8  seconds  after  the  last  key  is  pressed.  This 

allows the light to stay on if you need to operate several keys. 

Note:  If  the  thermostat  is  in  Low  Battery  warning  condition,  the  backlight  will  not 

operate. Replace with 2 new AA alkaline batteries to restore the Backlight function. 

Low Battery Warning 

Your  thermostat  has  a  two­stage  lower  battery  warning  system. 

When  the  batteries  are  first  detected  to  be  weak, the  first stage 

low  battery  warning  is  indicated  by  “BATT”  flashing  on  the  LCD 

display.  At  your  earliest  convenience,  you  need  to  replace  the 

batteries with 2 new AA alkaline batteries. 

When the  batteries  become  too  weak  for  normal  operation,  the 

thermostat  enters  the  second  stage  low  battery  warning  which 

shuts  down  the  thermostat.  In  this  condition,  “BATT”  flashes 

alone on the display, and the thermostat will turn your system off. 

Your system will remain shut­off until the batteries are replaced. 

Note: The thermostat will still keep the current Set Temperature and Filter run time in 

memory until new batteries are installed. After confirming that new batteries have been 

inserted, the thermostat will return to normal operation. 

Auto Recovery 

Auto  Recovery  calculates  how  early  to  turn  you  system  back  on,  so  that  the  room 

temperature  is  already  comfortable  by the  start  of  the  comfort  temperature  program 

period. Auto Recovery work’s in both Heat and Cool modes. 

ŸWhen the thermostat is in Auto Recovery mode, the display will 

alternate “RECO” with time, and the program indicator will flash. 

ŸAuto Recovery can be disabled by sliding the Recovery switch 

on the circuit board to disable. 

ŸAuto Recovery will not operate if Permanent hold or Temporary 

hold is in operation. 

ŸAuto  Recovery  can  be  canceled  manually  if  Hold/RETURN  is  pressed  during  the 

recovery process. 

ŸAuto Recovery will be canceled and change to next period. 

Error Mode 

If  the  thermostat  is  unable  to  control  your  system  due  to  an 

unexpected battery problem, the thermostat will enter Error Mode. 

In  this  condition,  the  thermostat  flashes  “E1”or  “E2”on  the  LCD 

display,  and  shuts  off  your  system.  To  correct  this  problem, 

replace the batteries with 2 new AA alkaline batteries, even if you 

have recently replaced them. Move the battery out hold any key then place the battery 

again. You will need to reprogram your thermostat and confirm normal operation. 

If Error Mode returns, please call us for further information. 

Lcd display 

information 

Lcd display 

information 

E1 

Sensor Error 

E2 

System switch 

Auto Cut Off 

Your  thermostat  will  automatically cutoff  in  Heat  mode  if  the  room temperature  rises 

above 95˚F (35˚C). It will cutoff in Cool mode if the room temperature drops below 45˚F 

(7˚C). 

Note:  that  if  your  system  has  malfunctioned  and  no  longer  responds  to  thermostat 

controls, the Auto Cut­Off will have no effect. 

day/time 

day/time 

hold 

/return 

heat 

off 

cool 

system 

p ro g r a m 

day/time 

day/time 

da y/tim e 

program 

p ro g r a m 

p ro g r a m 

heat 

off 

cool 

system 

on  auto 

fan 

hold 

/return 

filter 

p ro g r a m 

p r o g r a m 

program 

hold 

hold 

/return 

hold 

/return 

hold 

/return 

hold 

/return 

filter

Advertising