heat

off

cool

system

auto

heat

off

cool

system

auto

on

auto

fan

HOUR

DAY

HOLD

CLEAR

HOLD

CLEAR

6, When setting the program time, note the AM/PM indicator.
7, With the Auto Recovery feature enabled, you do not need to set your comfort program
times early. Auto Recovery will determine how early Recovery will determine how early
to turn your system on, so that the room is comfortable at the program time.
Weekday/Weekend Programming
Step1
■ Slide System Selector Switch to HEAT or
COOL to program the corresponding system.
NOTE: If the system selector is in the OFF position, no
programming is permitted. The LCD display will show only dashes
when the program key is pressed.
Weekday/ Weekend Programming (cont.)

Step2

Press PROG key to enter program mode,

display shows weekday programs.
Display for HEAT mode shown.

Step3 Use and to change the set point time.

Use and to change the set point temperature.

Step4 ■ Press to move to programs 2,3 and 4.

■Repeat Step3 to complete the weekday

programs.

Step5 ■ Press to change to the next day’s programs.

■Repeat Step 3 and 4 to complete the weekend programs

.

Step6 If you desire only weekend and weekday programs, press to RUN to

normal mode.

■ After 15 seconds, the thermostat will return to normal

mode automatically.

Step7

■ Change the System Selector Switch to the other system. And

repeat Step2 through 6 above.

7-DAY Programming

Step1 ■ Slide System Selector Switch to HEAT or

COOL to program the corresponding system.

Step2 ■ Press to enter program mode, display shows

weekday programs.

Step3 Use and to change the setpoint time.

Use and to change the setpoint temperature.

Step4 ■ Press to move to programs 2, 3 and 4.

■ Repeat Step 3 to complete the programs for Monday.

Step5 ■ Press to change the next day’s programs.

■ Continue repeating Step3,4 and 5 to

program all 7 days of the week.

Step6 ■ When finished press to return to normal mode.

After 15 seconds, the thermostat will return to

normal automatically.

7-Day Programming (continue)

Step 7 ■ Change the System Selector

Switch to The other system,
and repeat 2 through 6 above.

Reviewing Programs
You may want to review the programs to confirm that the settings are
compatible with your lifestyle.
Weekday Programs ■ Press to display M-F programs.

Press repeatedly to cycle through the 4 programs.

Weekend Programs ■ Press to display the Sa-Su
programs.

■ Press repeatedly to cycle through the 4


Daily Programs ■Press to display M-F programs.
NOTE: Time and Temperature display will be blank when at least
one weekday program is different.
■ Press to change to Sa-Su. Again, if the display is blank , one
of the weekend programs is different.
■ Press again to change to Monday’s program.
Continue pressing to cycle through each day.
■ Press repeatedly to cycle through the 4 programs.
■ Press to return to normal mode.
After 15 seconds, the thermostat will return to normal mode. automatically .
NOTE: Programs take affect as soon as the thermostat returns to normal mode.
If you are armchair programming the thermostat, slide the system selector to the OFF

position before mounting the thermostat to the wall plate.

Reviewing the Current Temperature Setting
Current time and temperature.

■ Thermostat is set to AUTO , and the heating system is

on.

■ Press for 1 second or less.
■ Set Temperature is shown above current room

temperature.

OPERATION

System Selector Switch

The System Selector Switch on the front of the thermostat determines

the

Operating mode of the thermostat. You may select COOL ,OFF ,
HEAT,AUTO. In order to take full advantage of this thermostat’s
feature, we recommend using the AUTO mode. Refer to the Auto
Season Changeover information on Auto Season Changeover..
NOTE: Anytime you install or remove the thermostat form the wallplate, slide the System
Selector to the OFF position to prevent the possibility of a rapid system On-Off.
Fan Switch
The Fan switch should normally be located in the AUTO position.
The Fan will be turned on along with normal operation of your
system. In a normal gas or oil furnace, the Fan will be turned on by
your furnace after its warm-up delay. For electric heat, air conditioning, and heat pump
operation, the Fan will turn on with the system. To run the Fan on continuously, slide the
Fan switch to the ON position.
Temporary Manual Override
To temporarily change the current set temperature without affecting your program:

■ Press and hold or for less than 1 second to enter
Manual Override mode..
■ Press and to change to your desired new

temperature.

■ Press to RUN to normal mode, or wait 15 seconds for it to return

automatically.

■ The current program number will flash to signify the Temporary Override.
At the next program change, the Temporary Override, and the next program
temperature becomes the set point temperature. To end the Temporary
Manual Override:
■ Press and wait for HOLD to display on the LCD.
■ Press hold key. This will return the set temperature to the current program
set temperature.

NOTE: The Auto Season Changeover feature will not operate while the thermostats is

in Temporary Manual Override .Refer to the Auto Season Changeover feature for more
information.
NOTE; If the thermostat has not been programmed, then a Temporany Override
becomes a Permanent Override. See the next section for more information.

Programming Your Thermostat (Continued)

Permanent Override or a Designated Day Override

To hold your Manual Override for vacation or Until a Designated Day

y

Press to make the current program temperature the

HOLD temperature. HOLD will be displayed on the LCD,

and the Program number will disappear.

y

Follow the Temporary Manual Override instructions

above to change the
Permanent Manual Override temperature.

y

You can confirm the held set temperature by pressing for less than 1 second.

y

Press again. Hold day will be displayed on the lcd and the clock

will disappear
y

Press Day key to add override days. Press Program key to

reduce override days
y

Follow the Temporary a Designated Day Override instructions above to

change the Permanent Manual Override temperature.

To end Override:
y

Under Permanent Override Press hold/return key twice. Under a Designated Day

Override press the hold once. The thermostat will return to the current program, and the
HOLD display will be canceled.
NOTE: The Auto Season Changeover feature will not operate while the thermostat is in
permanent Manual Override .Refer to the Auto Season Changeover feature for more
information.
Auto Season Changeover
When the System Selector is in AUTO position , the thermostat will automatically
change between Heating and Cooling systems, depending on your program .We
recommend keeping your programmed heating and cooling temperature at least 4˚F
(2˚C) apart to allow the Auto Season Changeover to occur when the appropriate
temperature span has been reached. However, if your heating and cooling programs set
temperatures are close, there is a built-in program to prevent the thermostat is in
Temporary, a Designated Day Override or Permanent Override , as these overrides are
energy saving settings. Auto Season Changeover will still function in Home Today mode,
as this is a comfort setting.
For example, you may have the following temperatures programmed at a given time:
Heat Set Temp=68˚F Cool Set Temp=78˚F
If the room temperature rises above 78˚F, then the thermostat will automatically change
to cool mode and turn on the air conditioner.
Likewise, the thermostat will automatically change to heart mode and turn
On heat when the room temperature falls below 68˚F.
HOME TODAY
This patent pending feature allows you to quickly and temporarily override your energy
saving program setting on days when you are normally away from home with one key
press.

■ Press to enter the Home Today override .The highest program temperature for
today will be selected from your programs in Heat mode
and become the set temperature.(In Cool mode ,Home
Today will select the lowest program temperature for today
to be the set temperature.)
■ The display will alternate between “HOME” and the current time.
■ When pressed during the day, the thermostat will remain in Home Today mode
until the first program of the next day.

■If the system is changed between Heat and Cool modes (either manually or by

Auto Season Changeover) during the “Home Today” override period, the setpoint
temperature will be automatically update.It will automatically change from the highest
heat program setpoint to the highest heat program setpoint .

■ Press to exit Home Today mode before the schedule ending time. “Home
Today” override period, the setpoint temperature will be automatically updated. It
will automatically change from the lowest cool program setpoint to the highest
heat program setpoint.
■ Press to exit Home Today mode before the schedule ending time.”HOME” is no
longer displayed on the LCD screen, and the thermostat returns to the current
program.
■ You can manually change the setpoint temperature while in Home Today mode.
Refer to the Temporary Manual Override instructions .Manually changing the set
temperature while in Home Today mode will not affect the Home Today ending
time, However, the set temperature will not change automatically with a manual
or Automatic change between heating and cooling.

Energy Monitor

■ The Energy monitor feature measures and stores the
amount of time the heating and air conditioning system
operates. Usage can be display for Today (since 12 am),
Yesterday, This Week (since Monday), Last Week (last
Monday through Sunday), and Total (up to 999 Hrs).By monitoring your energy
usage, you see how much the set-back periods are saving , and you can test
program adjustment to save even more. To review energy usage, press to cycle
through Today, Yesterday, this Week, Last Week, and Total. Press again to return
to normal mode, or wait 15 seconds for the display to return to normal mode .You
can also return to normal mode at any time by pressing RERURN.
■ For example: This LCD display shows Today’s usage to be 10 Hours, 26
minutes.
■ Press and hold for 3 seconds to reset the Energy Monitor’s counters.
The display will blink, and counters will be cleared to zero.

NOTE: Clearing the Energy Monitor counter will also clear the Filter Monitor
counter , as Filter usage and Total Energy usage are the same. Also, clearing the
filter Monitor counter will clear ALL Energy Monitor counters as well.
Filter Monitor
Your thermostat also keeps a record of the number of hours your filter has been in use.
To maximize your system’s performance and energy
efficiency, change or clear your filter regularly.
■ When the total system run time for heat and cool reaches 500
hours, you to clean or change your system’s filter, “FILT” will
contunre to flash until the counter is set back to zero.
■ Press to review total filter usage. The display will blink “FILT”
Then show the filter Monitor counter. After 15seconds, the display
will return to normal mode, or you can hit RETURN to exit
immediately.
The Filter Monitor will display up to 999 hours and 59 minutes of
usage. In this example, the counter is at 410 Hours, 26 minutes.
■ To reset the Filter Monitor counter, depress FILTER for 3 seconds. The display will
blink, and The counter will be reset to zero.
NOTE: Clearing the Filter Monitor counter will also clear ALL Energy Monitor
counters, as Filter usage and Total Energy usage are the same. Also, clearing the
Energy Monitor counters will clear the Filter Monitor counter as well.
Auto Recovery
Auto Recovery calculates how early to turn you system back on, so that the room
temperature is already comfortable by the start of the comfort
temperature program period. Auto Recovery work’s in both Heat
and Cool modes.

y

When the thermostat is in Auto Recovery mode, the display will

alternate “RECO” with time, and the program indicator will flash.
y

Auto Recovery can be disabled by sliding the Recovery switch on

the circuit board to disable.
y

Auto Recovery will not operate if Permanent hold or Temporary hold is in operation.

y

Auto Recovery can be canceled manually if Hold/RETURN is pressed during the

recovery process.
y

Auto Recovery will be canceled and change to next period.

Details of Auto Recovery Operation:

■ Auto Recovery can be disabled by sliding the Recovery switch on the circuit board

to the ALT position.

■ Today is in operation.
■ Auto Recovery can be canceled manually if HOLE/CLEAR is pressed during the

recovery process. If a recovery process is canceled manually then the recovery process
will not start again until the next program period starts (an exception is that if time or
program is changed then the thermostat will check Auto Recovery conditions
immediately).
■ Auto Recovery will be canceled and change to Home Today mode if HOME TODAY
is pressed during the recovery process.
Keyboard lock
The keyboard can be locked to prevent unauthorized changes to the thermostat.
■ To lock or unlock the keyboard, press and hold BOTH the
Keys for 3 seconds. The keyboard is locked when LOCK appears
on the display.
■ All keys are locked, Any time a key is pressed, LOCK will appear
on the display for 1 second.
Backlighting
Your thermostat has an electroluminescent lamp that backlights the display for easy
viewing in the dark.
When any key is pressed the display is illuminated.
The display will remain illuminated for 8 seconds after the last key is pressed. This
allows the light to stay on if you need to operate several keys.
Note: If the thermostat is in Low Battery warning condition, the backlight will not operate.
Replace with 2 new AA alkaline batteries to restore the Backlight function.
Low Battery Warning
Your thermostat has a two-stage lower battery warning system. When the batteries are
first detected to be weak, the first stage low
battery warning is indicated by
battery symbol flashing on the LCD display. At your earliest
convenience, you need to replace the batteries with 2 new AA
alkaline batteries.
When the batteries become too week for normal operation, the
thermostat enters the second stage low battery warning which shuts
down the thermostat. In this condition, “BATT” flashes alone on the
display, and the thermostat will turn your system Off. Your system
will remain shut-off until the batteries are replaced.
Note: The thermostat will still keep the current Set Temperature and Filter run time in
memory until new batteries are installed. After confirming that new batteries have been
inserted, the thermostat will return to normal operation.

Error Mode

If the thermostat is unable to control your system due to an unexpected battery problem,
the thermostat will enter Error Mode. In this condition, the
thermostat flashes “E1”or “E2”on the LCD display, and shuts off
your system. To correct this problem, replace the batteries with 2
new AA alkaline batteries, even if you have recently replaced them.
Move the battery out hold any key then place the battery again. You
will need to reprogram your thermostat and confirm normal
operation.
If Error Mode returns, please call us for further information.

Auto Cut Off
Your thermostat will automatically cutoff in Heat mode if the room temperature rises
above 95˚F (35˚C). It will cutoff in Cool mode if the room temperature drops below
40˚F (4˚C).
Note that if your system has malfunctioned and no longer responds to thermostat
controls, the Auto Cut-Off will have no effect.
Wiring Diagrams






















TROUBLESHOOTING

Problem

Solution

SCRAMBLED OR
DOUBLE DISPLAY
(numbers over
numbers)

1. Remove clear mylar sticker.

NO DISPLAY

1.

Check battery connections and batteries

2. Move the battery out hold any key then place. The
battery again.

ENTIRE DISPLAY
DIMS

1. Replace Batteries

PROGRAM DOES
NOT CHANGE AT
YOUR DESIRE
SETTING

1. Check that the time is set properly to “AM” or “PM”
2. Check that the thermostat is not in “HOLD” o r“ Home

Today” mode.

3. Check for the correct day settings.

AUTO/FAN DOES
NOT TURN ON GO
ON OR OFF

1

,Move HG/HE selector to opposite position is in the correct position

(“HEAT,”COOL” or “AUTO”)
2

,The thermostat may be in the AUTO Mode. Look for ”AUTO”

on the LCD display. If the Heat and Cool program temperature
are close, then the thermostat requires a larger room temperature
change before changing from Heat or Cool.
3

,There may be as much as 4 minute delay before the Heat or

Cool system turns On-wait and check. (Compressor protection
delay).
4

,Check your circuit breaks and switches to ensure there is

power to the system.
5. Replace batteries.
6. Make sure your furnace blower door is closed properly.
7. If your system only uses 4-wires, be sure the jumper wire is
installed between the RC and RH terminals.
8. Check the position of the Furnace or Heat Pump selector
switches: Normal/O/B.

Problem (cont.)

Solution (cont.)

ERRATIC DISPLAY 1. Move the battery out hold any key then place the battery

again.

IF UNIT CONTINUES
TO OPERATE IN
THE OFF POSITION

1. Replace unit

THERMOSTAT
PERMANENTLY
READS“HI”, “LO,”
OR “ERR-” AFTER
PRESSING
TER PRESSING

1. Replace unit.

If you experience any other problems, call us for technical assistance.

The service number is 1-866-591-9898

heat

off

cool

system

auto

heat

off

cool

system

auto

heat

off

cool

system

auto

HO LD

CLEAR

HOME

TODAY

R C

RH

G

Y

THERM OSTAT

O /B

RC

RH

G

Y

THERMOSTAT

O/B

RC

RH

G

Y

THERM OSTAT

O/B

RC

RH

G

Y

THERMOSTAT

O/B

RC

RH

G

Y

THERMOSTAT

O/B

RC

RH

G

Y

THERMOSTAT

O/B

PROG

DAY

PR O G

H O U R

MIN

PRO G

DAY

RUN

PROG

DAY

H O U R

MIN

RUN

PR O G

PR O G

PR O G

PROG

DAY

PR O G

PR O G

D AY

RUN

PR O G

ENER

ENER

HOLD

CLEAR

R UN

Advertising