Mode:CP2802

FEATURES

Structure of thermostat and explanation for the keypads





We are pleased you have selected one of our broad line of wall thermostat.
Our products are manufactured to high quality standards and are

designed

for years of service.

Read This Before Installing Thermostat

OPERATION

YOUR THERMOSTAT REPLACES

Description CP2801

Heat Pump (No Aux. or Emergency Heat)

Yes

Heat Pump (with Aux. or Emergency Heat)

Yes

Standard Heat & Cooling Systems

Yes

Two Stage Heat & Two Stage Cool

Yes

Standard Heat Only Systems

Yes

Millivolt Heat Only Systems– Floor or Wall

Furnaces

Yes

Standard Central Air Conditioning

Yes

Gas or Oil Heat

Yes

Electric Furnace

Yes

Hydronic (Hot Water) Zone Heat-2 Wires

Yes

Hydronic (Hot Water) Zone Heat–3 Wires

No

This Thermostat will NOT control 110/220Volt systems.

IMPORTANT

2, Read the entire installation section of this Owner’s Manual thoroughly
before you begin to install or operate your Thermostat.
REMOVE THE MYLAR LABEL FORM THE LCD DISPLAY WINDOW.

INSTALLATION

3, All installation is normally performed at your thermostat.

COMPRESSOR PROTECTION

4

,The thermostat provides a 4 minutes delay after shutting of the heating or

cooling system before it can be restarted. This feature will prevent damage
to your compressor caused by rapid cycling. Note that this delay also applies
to the heating system control. It does not provide a delay when there are
power outages.you can select the function on or off at the configuration.

TEMPERATURE RANGE

5,This thermostat can be programmed between 45˚F and 95˚F (7˚C and
35˚C). However, it will display room temperatures from 30˚F to 99˚F (0˚C and
37˚C). “HI” will be displayed if the temperature is higher than 99˚F (37˚C),
and “LO” will be displayed if the temperature is lower than 30˚F (0˚C).This
thermostat will automatically cutoff in Heat mode if the temperature rises
above 95˚F (35˚C), and automatically cutoff in Cool mode if the temperature
drops below 45˚F (7˚C).
NOTE: The thermostat will automatically change to the Cool mode if the
thermostat measure a temperature over 99˚F(37

℃), ”HI” will be displayed on

the LCD, and the Cooling system will turn On. Similarly, the thermostat will
automatically change to the Heat mode if the temperature is below 32˚F(0

℃).

and ”LO” will be displayed on the LCD, and the Heating system will turn On.

POWER FAILURE

6

, Whenever the main power is interrupted or fails, the battery power

retains and current time. This thermostat has permanent memory, although
you will have to reset your clock when there are power outages.

POWER SUPPLY

7

,The thermostat shall be powered by 24 VAC and with batteries as backup.

BATTERY WARNING

8

,Fresh alkaline batteries should provide about one year of service.

However, when the batteries become drained, “BATT” will alternate on the
display with the current time. When this message occurs, install 2 new AA
batteries, You have approximately 1 minute to change the batteries and keep
thermostat’s clock. Once the batteries have become too low to ensure
proper operation, your system will be turned off, and the display will be
cleared except for “BATT” flashing on the LCD display.

CAUTION:

Once only the “BATT” only display occurs, the thermostat is shut

down, and your system will no longer operate. In this condition,
there is no temperature control of your dwelling. NOTE: The

backlight will not function when the thermostat is in low battery condition.

NOTE: If you plan to be away from the premises over 30 days, we

recommend that you replace the old batteries with new alkaline

batteries prior to leaving.

INSTALLATION

What You Need
This thermostat includes two #8 slotted screws and two wall anchors for
mounting. To install your thermostat, you should have the following tools and
materials.
■ Slotted Screwdriver(s) ■ Small Philips screwdriver ■ Hammer

■ Electric drill and 3/16” bit ■ Two1.5V (AA) size alkaline batteries
(included)

CAUTION:

To prevent electrical shock and/or equipment damage, disconnect

electric power to system at main fuse or circuit breaker box until

installation is complete.

Before removing wires from old thermostat's switching subbase, label each
wire with the terminal designation it was removed from.
1. Shut off electricity at the main fuse box until installation is complete.
Ensure that electrical power is disconnected.
2. Remove Old Thermostat: A standard heat/cool thermostat consists of
three basic parts:
a. The cover, which may be either a snap-on or hinge type.
b. The base, which is removed by loosening all captive screws.
c. The switching subbase, which is removed by unscrewing the mounting
screws that hold it on the wall or adaptor plate.
3. Remove the front cover of the old thermostat. With wires still attached,
remove wall plate from the wall. If the old thermostat has a wall mounting
plate, remove the thermostat and the wall mounting plate as an assembly.
4. Identify each wire attached to the old thermostat.
5. Disconnect the wires from the old thermostat one at a time. DO NOT LET
WIRES FALL BACK INTO THE WALL.
6. Install new thermostat using the following procedures.

WARNING

Do not use on circuits exceeding specified voltage. Higher voltage will

damage control and could cause shock or fire hazard. Do not short out

terminals on gas valve or primary control to test. Short or incorrect

wiring will damage thermostat and could cause personal injury and/or

property damage.

Selector Switches

Electric/Gas Switch (Fan Option)

Figure 1. Electric/Gas Switch (Fan Option)

This thermostat is configured from the factory to operate a heat/ cool, fossil
fuel (gas, oil, etc.), forced air system. It is configured correctly for any system
that DOES NOT require the thermostat to energize the fan on a call for heat.
If you system is an electric heat or heat-pump system that requires the
thermostat to turn on the fan on a call for heat, locate the ELEC/GAS switch
on the back of the thermostat (see fig. 1) and switch it to the ELEC position.
This will allow the thermostat to energize the fan immediately on a call for
heat. If you are unsure if the heating/ cooling system requires the thermostat
to control the fan, contact a qualified heating and air conditioning service
person. When the thermostat is configured for Heat Pump, the thermostat
will always power the circulator fan on a call for heat in the HEAT mode. The
ELEC/GAS switch must be set to match the type of Auxiliary heat your
system uses for proper operation in the EMERgency mode.
All wiring diagrams are for typical systems only. Refer to equipment
manufacturers’ instructions for specific system wiring information.

Attach Thermostat Base to Wall

1. Remove the packing material from the thermostat. Gently pull the cover
straight off the base. Forcing or prying on the thermostat will cause damage
to the unit.
2. Connect wires beneath terminal screws on base using appropriate wiring
schematic (see figs. 2 through 4).
3. Place base over hole in wall and mark mounting hole locations on wall
using base as a template.
4. Move base out of the way. Drill mounting holes.
5. Fasten base loosely to wall, as shown in fig. 1, using two mounting screws.
Place a level against bottom of base, adjust until level, and then tighten
screws. (Leveling is for appearance only and will not affect thermostat
operation.) If you are using existing mounting holes, or if holes drilled are too
large and do not allow you to tighten base snugly, use plastic screw anchors
to secure subbase.
6. Push excess wire into wall and plug hole with a fireresistant material (such
as fiberglass insulation) to prevent drafts from affecting thermostat operation.










Figure 2. Thermostat base





Figure 3 Typical wiring diagram for single transformer heat pump

systems



Figure 4. Typical wiring diagram for two transformer heat pump

systems with NO safety circuits

Figure 5. Typical wiring diagram for two transformer heat pump

systems with safety circuits in BOTH systems

Heat Pump Terminal Outputs

Refer to equipment manufacturers' instructions for specific system wiring
information. You can configure the thermostat for use with the following heat
pump system types: HEAT PUMP TYPE 1 1. Single stage compressor
system; gas or electric backup. This thermostat is designed to operate a
single-transformer system. If you have a two-transformer system, cut and
tape off one transformer. If transformer safety circuits are in only one of the
systems, remove the transformer of the system with NO safety circuits. If
required, replace remaining transformer with a 75VA Class II transformer.
After disconnecting one transformer, the two commons must be jumpered
together.
Use the terminal output information below to help you wire the thermostat
properly for your heat pump system. After wiring, see CONFIGURATION
section for proper thermostat configuration.

THERMOSTAT TERMINALS (HEAT PUMP)

SYSTEM

Heat Pump 1

Heat Pump 2

L Malfunction

C* 24

Volt(Common)

R

24 Volt Emergency (hot)

E/W1

Emergency Mode 1st stage

W2

HP 1 and Emergency 2nd stage

Y1

Heat and Cool mode 1st stage (compressor)

Y2

No output

2nd stage compressor

G

Blower/Fan Energized on call for Heat and Cool

Set GAS/ELEC switch for Emergency mode

O

Energized in Cool Mode

B

Energized in Heat Emergency mode






Figure 5. Typical wiring diagram for single transformer multi-stage

systems

CHECK THERMOSTAT OPERATION

Note:

To prevent static discharge problems, touch side of thermostat to

release static build-up before touching any keys.

If at any time during testing your system does not operate properly,

contact a qualified serviceperson.

Fan Operation

If your system does not have a G terminal connection, skip to Heating
System System.
1. Turn on power to system.
2. Move FAN switch to ON position. The blower should begin to operate.
3. Move FAN switch to AUTO position. The blower should stop immediately

Heating System

1. Move system switch to heat mode. If the auxiliary heating system has a
standing pilot, be sure to light it.
2. Press to adjust thermostat setting to 1

℃ above room temperature. The

heating system should begin to operate. The display should show “STG1”.
However, if the setpoint temperature display is flashing, the compressor
lockout feature is operating (see Configuration menu, item 5).
3. Adjust temperature setting to 3° above room temperature.If your system
configuration is set at MS2, HP2 or HP1, the auxiliary heat system should
begin to operate and the
display should show “STG1+2”.
4. Press to adjust the thermostat below room temperature. The heating
system should stop operating.

Emergency System

EMER bypasses the Heat Pump to use the heat source wired to terminal E
on the thermostat. EMER is typically used when compressor operation is not
desired, or you prefer back-up heat only.
1. Press SYSTEM switch to select Heat mode. then press EMER key..
“EMER” will show on the display.
2. Press to adjust thermostat setting above room temperature. The Aux.
heating system will begin to operate. The display will show “STG1” “EMER”
to indicate that the Aux. system is operating.
3. Adjust temperature setting to 2°C above room temperature.The auxiliary
heat system should begin to operate and the display should show “STG1+2”.
4. Press to adjust the thermostat below room temperature. The Aux. heating
system should stop operating.

Cooling System

1. Move SYSTEM switch to select the Cool mode.
2. Press to adjust thermostat setting below room temperature. The blower
should come on immediately on high speed, followed by cold air circulation.

Mounting
Hole

Mounting
Hole

GA
S

ELEC

K2

Elec-Gas

Switch

TIME

ENER

EMER

RUN

Measures and displays

heating and cooling system

operating time for Today,

Yesterday,This Week,Last

Week,or Total.By monitoring

your energy usage,you can

program the thermostat to
optimize energy savings.

For entering Time

Returns display to current time and temperature.

EMER Mode

heat

off

cool

on

auto

TIME

ENER

EMER

RUN

system

fan

LCD Display:Shows
Time,Day,Temperature,
and other feature
information as required.

F

Backlight key

Battery Compartment:
Front access allows
easy insertion of two
AA 1.5V batteries.

Up and Down Key:Key for
changing the Temperature
setting. Also used for increasing
and decreasing selections in the
Time,and Span functions.

/return

Fan Switch: Fan
switch for Automatic
or Continuous fan
operation.

System Switch:
Selector switch for
Heat,Cool,and Off.

For entering Time

EMER Mode

Returns display to current
time and temperature.

Front Door:
Battery cover
Open with one
finger from top.

Front Door: Cover keys Open with one finger from left or right.

Measures and displays

heating and cooling system

operating time for Today,

Yesterday,This Week,Last

Week,or Total.

O

B

Y2

G

C

L

R

Y1

W2

Reversing
Valve
Energized in
Cool Mode

Reversing
Valve
Energized in
Heat, Off,
Emergency
Mode

2nd Stage
Compressor

THERM OSTAT

SYSTEM

Fan
Relay

Emergency
Heat
Relay

Compressor
Contactor

Aux
Heat
Relay

SYSTEM

M ONITOR

SWITCH

E/ W1

Hot
120 VAC
Neutral

TRANSFORMER
(Class

Current Limited)

24 VAC

NEUTRAL

CUT AND

TAPE OFF!

TWO COM M ONS M UST

BE JUM PERED TOGETHER!

HOT

120 VAC

24 VAC

Limit or Safety
Switches

O

B

Y2

G

C

L

R

Y1

W2

Reversing

Valve

Energized in
Cool Mode

Reversing

Valve

Energized in

Heat, Off,

Emergency

Mode

2nd Stage
Compressor

THERMOSTAT

SYSTEM

Fan
Relay

Emergency
Heat
Relay

Compressor
Contactor

Aux
Heat
Relay

SYSTEM

MONITOR

SWITCH

E/ W1

Hot
120 VAC
Neutral

TRANSFORMER

(Class Current Limited)

24 VAC

O

B

Y2

G

C

L

R

Y1

W2

Reversing
Valve
Energized in
Cool Mode

Reversing
Valve
Energized in
Heat, Off,
Emergency
Mode

2nd Stage
Compressor

THERMOSTAT

SYSTEM

Fan
Relay

Emergency
Heat
Relay

Compressor
Contactor

Aux
Heat
Relay

SYSTEM

MONITOR

SWITCH

E/ W1

TWO COMMONS MUST

BE JUMPERED TOGETHER!

Limit or
Safety
Switches

24VAC

ACCESSORY

RELAY N.O.

CONTACY

Limit or
Safety
Switches

HOT

120 VAC

Heat Pump Transformer
(Class Current Limited)

24 VAC

Limit or Safety
Switches

COMMON

HOT

120VAC

Auxiliary
Heating
Transformer
(Class
Current Limited)

24VAC

Limit or
Safety
Switches

NEUTRAL

NEUTRAL

COMMON

NOTE
The accessory relay scheme
is required when safety
circuits ezist in both systems

O

B

G

C

R

Y2

W2

Reversing

Valve

Energized in
Cool Mode

Reversing

Valve

Energized in

Heat, Off,

Emergency

Mode

THERMOSTAT

SYSTEM

Fan
Relay

Heat
Relay
Stage 1

Compressor
Contactor
Stage 1

E/ W1

Hot

120 VAC

Neutral

TRANSFORMER

(Class Ⅱ Current Limited)

24 VAC

Heat
Relay
Stage 2

Y1

Compressor
Contactor
Stage 2