ASUS GUI RAID Manager: Array Management

4.6 Setting Channel Configuration

4-13

enable the write-back cache, select Enabled; to disable,
select Disabled.

4. If you want a SCSI bus reset to be issued on the drive

channels every time you power on or reset the disk array
system, set the SCSI Reset on Power-Up parameter to
Enabled. Otherwise, set this parameter to Disabled.

5. To avoid overloading the power supply when several drives

spin up at the same time, set the Staggered Drive Spin-Up
parameter to Enabled. If a fast system startup is needed,
and the power supply is capable of handling all the power
requirements of the drives at the same time, set this
parameter to Disabled.

6. Use the RS-232 Baud Rate drop-down list box to set the

baud rate of the RS-232 port on the controller. If you have a
host computer, terminal, or other device (such as a modem)
connected to this port, specify here the baud rate of the
connected device, or set the port’s baud rate here and make
the baud rate of the device correspond to this value.

7. If you want to modify the password, check the Change

Password check box, and then specify the new password in
the provided text box. You will need to confirm your
password.

8. Click OK to save the new controller configuration. If you

specified a new password, this value will be saved into the
non-volatile memory on the disk array controller.

4.6 Setting Channel

Configuration

From within the GUI RAID Manager, you can modify the
configuration of any channel on the controller. You can set the