Trouble-Shooting

Problem:

Possible reason:

Remedy:

SHAVER

Unpleasant
smell from the
shaver head.

1. Shaver head is

cleaned with water.

2. Cleaning cartridge is

in use for more than
8 weeks.

1. When cleaning the shaver head

with water only use hot water
and from time to time some
liquid soap (without abrasive
substances). Remove foil &
cutter cassette to let it dry.

2. Change cleaning cartridge at

least every 8 weeks.

Battery
performance
dropped
significantly.

1. Foil and cutter are

worn which requires
more power for each
shave.

2. Shaver head is

regularly cleaned with
water but not
lubricated.

1. Renew foil & cutter cassette.
2. If the shaver is regularly cleaned

with water, apply a drop of light
machine oil on top of the foil
once a week for lubrication.

Shaving
performance
dropped
significantly.

1. Foil and cutter are

worn.

2. Personal setting of

shaving performance
has been changed.

3. Shaving system is

clogged.

1. Renew foil & cutter cassette.
2. For a thorough and fast shave

we recommend the «+»
(intensive) setting.

3. Soak the foil & cutter cassette

into hot water with a drop of
dish liquid. Afterwards rinse it
properly and tap it out. Once
dry apply a drop of light
machine oil on the foil.

Shaver turns off
after 1 minute
shaving time
with fully
charged battery.

Foil and cutter are worn
which requires more
power than the motor
can deliver. The
appliance turns off.

– Renew foil & cutter cassette.
– Regularly oil the shaving

system, especially when
cleaning with water only.

Battery
segments in the
display are
skipped with
decreasing
battery capacity.

Foil and cutter are worn
which requires more
power for each shave.

– Renew foil & cutter cassette.
– Regularly oil the shaving

system, especially when
cleaning with water only.

Shaving parts
have been
changed recently
but replacement
symbol lights up.

Reset button has not
been pushed.

– Push the reset button for at

least 3 seconds to reset the
counter.