Checking the drives for data consistency -27, 5 checking the drives for data consistency, Using the check consistency command – Asus P9D-I User Manual

Page 117: Asus p9d-i

Advertising
background image

ASUS P9D-I

5-27

2.

The screen displays the available RAID set(s) and prompts you to select the virtual
drive to check. Press <Space> to select the virtual drive from the

Virtual Drive

sub-menu then press <F10>.

5.2.5

Checking the drives for data consistency

You can check and verify the accuracy of data redundancy in the selected virtual drive. The
utility can automatically detect and/or detect and correct any differences in data redundancy
depending on the selected option in the

Objects > Adapter menu.

The

Check Consistency command is available only for virtual drives included in a RAID 1

or RAID 10 set.

Using the Check Consistency Command

To check data consistency using the

Check Consistency command:

1.

From the

Management Menu, select Check Consistency then press <Enter>.

Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option

LSI Software RAID Configuration Utility Ver C.05 Oct 26,2011

BIOS Version A.11.02090932R

CC of VD(s)

Configure

Initialize

Objects

Rebuild

Check Consistency

Management Menu

SPACE-(De)Select, F10-Initialize

LSI Software RAID Configuration Utility Ver C.05 Oct 26,2011

BIOS Version A.11.02090932R

Select VD

Configure

Initialize

Objects

Rebuild

Check Consistency

Management Menu

Easy Configuration - ARRAY SELECTION MENU

Virtual Drive(s) Configured

LD RAID Size #Stripes StripSz Status

0 1 148.580GB 2 64KB ONLINE

Virtual Drive 0

Virtual Drives

Advertising