Operational checks, After checking procedures – Armasight NSCCOLR00139DA1 CO-LR GEN 3 Alpha MG Night Vision Long Range Clip-On System User Manual

Page 30

Advertising
background image

30

SEq

NO.

LOCATION ITEM TO

CHECK/SERVICE

PROCEDURE

NOT FULLY MISSION

CAPABLE IF ...

5

Battery Compart-

ment/ Cap / Battery

Adapter

Check to make sure the battery adapter is present. Check for

corrosion, cap damage or retainer breaks. Check O-ring for

cuts or damage.

Retainer is broken. Cap, O-ring or battery

adapter is damaged or missing.

6

Switch

Check for operation (without battery).

Switch is inoperative.

7

Lenses

Inspect for cleanliness, scratches, chips or cracks. Clean as

required.

Chipped or cracked. Scratches hinder vi-

sion through the CO-LR.

8

Photoreceiver

Inspect for cleanliness, scratches. Clean as required.

Photoreceiver is damaged.

9

Focus Knob.

Gain Control Knob*

Check to ensure there is free rotation through full range of

travel.

Knob is inoperative.

Knob is missing

10

Advanced Wireless

Remote Control

Check for damage.
Check Velcro tape for wear.

Damaged. Unit or tape is missing.

11

Light Suppressor

Inspect for cuts or tears. Check ease of installation and re-

moval.

Light suppressor is torn or cut.

12

Mount

Inspect for damage or corrosion, and for missing parts.

Check for proper operation.

Damaged. Some parts are missing.

Clamping device is inoperative.

13

IR850 Body, Mount

Inspect for damage and missing parts. Check for proper

operation.

Damaged. Missing parts. Mount is inop-

erative.

14

IR850 Battery Cap,

Power Switch

Check O-ring for damage. Check for proper operation.

O-ring is damaged or missing. Switch is

inoperative.

15

IR850 Lens

Inspect for cleanliness, scratches, chips or cracks. Clean as

required. Check to ensure there is free rotation through the

full range of travel (1 turn).

Lens is chipped or cracked. Lens is stick-

ing when or too loose when turned.

16

Optional FSRS

System

Inspect for damage and missing parts. Check clamping de-

vices for proper operation.

Damaged. Missing of some parts. Clamp-

ing devices are inoperative.

OPERATIONAL CHECKS

CAUTION:

The objective lens cap has an optical filter, which allows operational testing of the CO-LR in daylight. Activate the CO-LR in daylight

only with the objective lens cap on or in dark conditions.
NOTE:

Daylight checks are described below.

17

CO-LR Switch

Insert the battery. Remove the output lens cap. Close the

photoreceiver by flipping up the pivotal shutter. Turn the

switch to ON position. Look for green glow (after a slight

delay) in viewing area.

No green glow.

Open photoreceiver by flipping the pivotal shutter down.

Look through the output lens and wait about 20 seconds for

the green glow to disappear.

Green glow is present, red glow is ab-

sent.

18

Remote Control

Put the unit in STB. Press and hold the remote control but-

ton. Look for the green glow in output lens. Release the but-

ton. Turn the device OFF.

Green glow is absent.

19

Focus Knob

Turn to the device ON. Rotate the knob to ensure it adjusts

for focus.

Knob does not adjust for focus.

20

Gain Control Knob*

Rotate the gain control knob to ensure it changes the

screen’s brightness.

Knob does not adjust the screen’s bright-

ness.

21

Viewed Image

Check for flickering, flashing, bright spots, edge glow, shad-

ing, or excessive fixed-pattern noise (honeycomb).

Excessive cosmetic defects or fixed pat-

tern noise is present.

22

IR850

Insert the battery. Mount the IR850 onto the CO-LR. Turn on

the IR850. Direct the radiated beam at a wall from a distance

of about 5m. Look through the CO-LR. A square of light

should appear on the wall.

No light appears on the wall.

AFTER CHECKING PROCEDURES

23

Turn off the IR850 and CO-LR. Replace the protective cap

over the CO-LR output lens.
Remove the battery.
Return the unit and all accessories to the storage case.

* For CO-LR MG version only

TABLE 4-1. CONTINUED